1.4.3 Digital input interfaces
The schematic diagram of the digital input interfaces is as follows:
Maximum absolute values
Unit
Minimum input voltage
- 0,7
V
Maximum input voltage
+50
V
Electrical Characteristics
Unit
Minimum input voltage
0
V
Maximum input voltage
24
V
Equivalent input resistance
500
kΩ
Input frequency
10
Hz
Current consumption input level HIGH
0
µA
Current consumption input level LOW
6
µA
Values above the absolute maximum values will damage the device.
1.4.4 Characteristics of the embedded sensors
Electrical Characteristics
Unité
Presence (PIR)
Maximum detection distance
5
m
Vertical opening angle
82
°
Horizontal opening angle
94
°
Minimum inhibition time after end of detec-
tion
10
s
Side View (Vertical)
Top View (Horizontal)
Notes on the presence sensor:
• The body to be detected must have a temperature differ-
ent by more than 4°C (+/-) from room temperature
• If the body to be detected has a temperature very differ-
ent from the ambient T°C, the detection distance and the
opening angle may be higher than the values indicated in
the table above.
• Sources of intense heat can blind the sensor
• The sensor will have trouble detecting through a window
(IR diffraction)
Electrical Characteristics
Unit
Luminosity
Measuring range
0 à 100
%
Resolution
1
%
The brightness measurement is a subjective measure representative of human perception given as 100%.
100% representing full daylight and 0% complete darkness.