6.2.2.3 Replace the bottom cover and converter
Remove
1. Disassemble the light fixture.
2. From inside the housing, disconnect all cables from the LED board.
Replace
1. Place the new gasket on the new bottom cover with converter.
2. Connect the LED board cable(s). Note the orientation and alignment of the cables in
and
.
Note
Make sure that light fixtures with only one LED-cable is connected to the LED B-channel.
Figure 29: Converter with 1 connector
Figure 30: Converter with 2 connectors
3. Assemble the light fixture.
6.2.3 Check the light fixture for water-tightness
If maintenance is carried out in a workshop, check the water-tightness of the light.
RELIANCE Inset Light
Maintenance
38