Remove the fitting from the base
CAUTION
Fall and Trip Hazard
When a light fixture has been removed, the base must be fitted with a cover designed for this purpose or with a spare
light fixture.
1. Remove the light fixture from the base using two large flat blade screwdrivers.
2. Disconnect the secondary supply connector.
3. Remove and check the O-ring gasket.
Note
It is recommended to change the gasket, lock nuts or bolts each time the light fixture is removed or dismounted from
the base.
CAUTION
Use of incorrect combination of gaskets, bolts and nuts can create severe damages to the product installation and
create multiple safety risks.
Make sure to know what base the light fixture will be installed in, in order to chose the correct gasket, bolts and nuts.
Failure to follow these cautions can result in equipment damage or aircraft FOD.
RELIANCE Inset Light
Installation
18
Copyright
©
ADB Safegate, All Rights Reserved