5. Replace the bottom cover and converter
6. Reset the Fail Open converter
6.2 Basic maintenance program
There are recommended maintenance tasks to ensure that the equipment is in correct operating condition.
Maintenance tasks
Weekly
•
Visual inspection of the light fixture.
•
Removal of dust from external surfaces of the light fixture.
Monthly
•
Check of the optical window, check for mechanical damage.
•
Check for proper fixing of the light fixture in its base.
Yearly
•
Detailed inspection of the light fixture.
•
Check of the body resistance, check for mechanical damage (for example cracks around prism windows).
•
Clean of the optical windows.
A daily function check is referred to in the document:
ICAO, Airport Services Manual Part 9, Airport Maintenance Practice and FAA AC 150/5340-26A,
Maintenance of airport visual aids facilities.
The light fixture is designed for outdoor operation, however storing the light fixture outside without using it is a risk for
damage to light fixture components. For a longer storage time (more than a week), it is recommended to store the light
fixture indoors in a dry and dust free environment and at room temperature. Proper storage ensures trouble free replacement
procedures. It is strongly recommended not to store any electrical equipment outside.
6.2.1 Workshop Maintenance 8" fixture
6.2.1.1 Open and close a 8" fixture
Remove
1. Place the light fixture upside down and remove the four screws for the bottom cover using an Allen key 4 mm, see
2. Lift up the housing and disconnect the LED board cable connector from the LED boards in the top cover, see
.
Note
Open the light fixture cautiously, be careful not to damage the LED-board cables.
RELIANCE Inset Light
Maintenance
30
Copyright
©
ADB Safegate, All Rights Reserved
Содержание RELIANCE IQ L-852G(L)
Страница 2: ......
Страница 12: ...RELIANCE Inset Light Safety 6 Copyright ADB Safegate All Rights Reserved ...
Страница 14: ...RELIANCE Inset Light About this Manual 8 Copyright ADB Safegate All Rights Reserved ...
Страница 20: ...RELIANCE Inset Light Introduction 14 Copyright ADB Safegate All Rights Reserved ...
Страница 50: ...RELIANCE Inset Light Spare parts 44 Copyright ADB Safegate All Rights Reserved ...
Страница 51: ...UM 0197 Rev 1 0 2019 11 19 45 Copyright ADB Safegate All Rights Reserved ...
Страница 52: ......