ADASH Ltd.
Adash 4300 – VA3Pro
For further technical and contact information visit www.adash.com, email: [email protected]
68
Next measurement uses the ACMT method. As you can see, it works. Long time signal contains required
number of pulses and the peak of each of them is captured. That is what we need.
The ACMT method can do even more
Short duration pulses have usually small amplitude. They are often modulated by speed frequency.
We use standard measurement and result is in the next picture.
You see only speed sine wave and none or small pulses, which are filtered by anti aliasing.
The standard ACMT is used in the picture below. We used the ACMT together with band pass filtering which
removes the speed sine wave from the signal.
The all short-pulses are held and amplitude is modulated for better view.
This result is much better, because Y axis scale corresponds with real pulses amplitude, not with speed sine
wave amplitude.