ADASH Ltd.
Adash 4300 – VA3Pro
For further technical and contact information visit www.adash.com, email: [email protected]
38
Channel, A channel number, B channel number
1, .., 3 Selection of the input signal source channel
Unit (name)
The selection of the required unit to be displayed.
Detect Type
RMS, Scaled 0-P, Scaled P-P, True 0-P, True P-P, AVG, Crest, Kurtosis
The detected value property ( P means Peak).
Scaled 0-P
it is equal 1.414 * RMS
True 0-P
it is true 0-peak value in the waveform (the highest value captured in time signal).
Scaled P-P
it is equal 2.828 * RMS
True P-P
it is true peak-peak value in the waveform (the difference between highest positive and highest
negative value in signal)
AVG
it is average value of all samples (total sum of absolute values divided by number of samples)
Crest
it is equal True 0-P/ RMS
Kurtosis
standard statistical formula for Kurtosis
Fmin [Hz] (value)
The low cut-off frequency of band pass filter, which is applied to the signal before further
processing (evaluation). The none value (available only when no integration is applied) means, that only input
DSP filter is applied (approximately 0.6 Hz).
Fmax [Hz] (value)
The high cut-off frequency of band pass filter, which is applied to the signal before
further processing (evaluation). The information about sampling frequency (fs=) is displayed under this item.
DEMOD fmin [Hz] (value)
The low cut-off frequency of band pass filter, which is applied to the signal
(removing low frequencies).
DEMOD fmax [Hz] (value)
The high cut-off frequency of band pass filter, which is applied to the signal
(removing high frequencies).
ACMT FS [Hz] (value)
The sampling frequency for ACMT evaluation. See the ACMT chapter for better
understanding.
Samples (value)
Number of samples (Speed control = off). The correspondent signal time length
is displayed under this item.
Lines (value)
Number of lines. The correspondent signal time length is displayed under this item.
Orders
(1/2,1-5), (1-5), (1/2,1-10), (1-10)
Averaging
linear, peak hold (for spectra)
linear, maximum, minimum, median (for static values)
Avg (value)
averaging number
How the averaging is used depends on the type of trigger:
freerun
when the measurement is started, the signal needed for averaging is taken continuously
external
when the external trigger comes, the signal needed for averaging is taken continuously
without waiting for next trigger
tacho
every signal for averaging is triggered (constant phase)
amplitude