ADASH Ltd.
Adash 4300 – VA3Pro
For further technical and contact information visit www.adash.com, email: [email protected]
27
Meter mode
It enables the user to perform basic vibrodiagnostics measurements.
Settings
Press the Menu and select the Meter Settings.
Channel:
Number of the input channel
Alarms:
Settings of standards which define the limit values for warning (orange colour) and danger (red colour);
see Appendix C: Standards for vibration measurements. The measured values are displayed in traffic
light colours.
You can select the Adash standards (recommended, default item) or the ISO 10-816 standards which
are much more general.
Colour indication according to ISO 10-816 standards are as follows: A and B range is displayed in green
C range is displayed in orange, D range is displayed in red.
Default: Adash limit values
R13, F13, R24, F24: limit values according to ISO 10-816
Sensor Settings
In the Sensors item set up the parameters of the chosen sensor. You need to use the accelerometer to display
all possible measurements. If you use a velocity sensor, the acceleration values will not be measured. If you use
a proximity sensor, the acceleration values and velocity values will not be measured.
Unit Settings
The displayed units can be set up under the Global item. Set up the unit of speed (Hz, RPM, CPS, CPM) in the
Speed Unit item. The vibration values are displayed according to the setting of Units (metric, imperial). The
temperature can be displayed in degrees of Celsius or Fahrenheit.
The units used are set up in Global/Units as follows:
metric:
acceleration - g
velocity - mm/s
displacement - µm
imperial:
acceleration - g,
velocity – in/s
displacement – mil