138
Software Installation and User’s Guide
ICP RAID Console
Use the
Hot Fix Pool Access
option to enable or disable the access of the selected array
drive to the hot fix pool.
Parity Verify
To access this function, from the Advanced Setup menu:
•
Select the
Configure Array Drives
option and press Enter to display the Select Array
Drive screen.
•
Select an array drive and press Enter to display the Array Drive window.
•
Select the
Parity Verify
option and press Enter.
The redundancy information calculated during an array
build
or
rebuild
is stored on a
dedicated logical drive (RAID 4), or is distributed over all logical drives of the array drive
(RAID 5). This information is often called
parity data
. The calculation is made with an
exclusive OR function (XOR). If a logical drive of an array drive fails, its data can be
recalculated by means of the data present on the other logical drives of the array drive and
the parity data. The
Parity Verify
function allows you to check the consistency of an array
drive's parity data. The verification may take quite a long time, but you can terminate it by
pressing <Esc>.
Note:
If you press the escape key <Esc>, the progress indicator (
Figure 10-87
) will close.
However, parity verify continues to run unless you press the <A> key to abort the parity
verify.
Note:
Parity verify has the capability to repair bad parity sectors automatically.
Figure 10-87. Progress Information
Periodic Parity Verify
To access this function, from the Advanced Setup menu:
•
Select the
Configure Array Drives
option and press Enter to display the Select Array
Drive screen.
•
Select an array drive and press Enter to display the Array Drive window.
•
Select the
Periodic Parity Verify
option and press Enter.
Allows you to schedule parity verify activity as described in previous section.
Configurable variables include:
Start Parity Verify
(frequency of days to run, default is
none),
At Time
(what time to run on the days specified), and
Error Handling
(what action
to take when an error in encountered during the parity verify).
Build/Rebuild Progress
To access this function, from the Advanced Setup menu:
•
Select the
Configure Array Drives
option and press Enter to display the Select Array
Drive screen.
•
Select an array drive and press Enter to display the Array Drive window.
Содержание 2074700-R - ICP Vortex GDT8514RZ RAID Controller
Страница 1: ...Preliminary ICP RAID Software Software Installation and User s Guide Version 1 2 7 June 2003 ...
Страница 23: ...Software Installation and User s Guide 23 Introduction ...
Страница 68: ...68 Software Installation and User s Guide Installing Linux ...
Страница 92: ...92 Software Installation and User s Guide Installing Berkeley UNIX FreeBSD ...
Страница 214: ...214 Software Installation and User s Guide Fibre Channel Features ...