110
Software Installation and User’s Guide
ICP RAID Console
Figure 10-50. Array Drive Summary
Press any key and ICPCON displays a list of array drives which are candidates for online
automatic repair.
Note:
Array drives that are in the
Error
state are very critical and have lost 2 or more drives.
These array drives cannot be repaired with the
Repair Array Drives
function. In such
critical cases, data integrity can no longer be maintained.
Select the array drive and ICPCON displays the drive that failed. For example, the hard
disk that forms logical drive 5 has a failed state in
Figure 10-51
.
Figure 10-51. Failed Hard Drive
After confirmation, the failed drive must be removed from the system and the new one
configured on the same ID and installed in the system. See
Figure 10-52
and
Figure 10-53
.
Figure 10-52. Replace Hard Drive Prompt
Figure 10-53. Replace Hard Drive Prompt
ICPCON detects the new drive and expects clearance to build this drive as a replacement
into the array drive. See
Figure 10-54
.
Figure 10-54. Add Disk to Array Confirmation