134
Software Installation and User’s Guide
ICP RAID Console
Figure 10-85. Expand Popup Window
The Expand popup window contains three major functions:
Note:
If the entire hard disk capacity is not used when configuring a RAID 1 host drive, you
cannot
use the remaining capacity to expand the array drive in the future.
Note:
If ICPCON is closed, migration of the RAID level may not complete.
To migrate or expand an array drive, the state must be
ready
. The data on the array drive
remains intact and is not affected by the expansion.
Warning:
When starting an expand process, the unused capacity of the current array
components (i.e. "Use free Logical Drive space") is activated and the drive enters a
build
state. At this point the array is put in the non-redundant build process, so it is
very important to create a full backup before you start this process. If during the
build process a disk fails, then the array changes to
idle = not functioning,
and the
expansion process continues until the array drive enters the
fail state
.
Add RAID 1 Component
The
Add RAID 1 Component
option allows you to add, to a logical drive which is member
of an array drive, another logical drive as a mirror drive (RAID 1).
To access this function, from the Advanced Setup menu:
•
Select the
Configure Array Drives
option and press Enter to display the Select Array
Drive screen.
•
Select an array drive and press Enter to display the Array Drive window.
•
Select the
Add RAID 1 Component
option and press Enter.
Example
: You have configured an array drive with 4 logical drives. One logical drive has
failed and the array drive has gone into the fail state. Another failure would cause data
loss. Unfortunately, you find another logical drive which is likely to fail (for example, you
hear a strange noise coming from it, or its grown defect counter explodes). If you initiate a
hot plug, it is very likely that this critical logical drive will also fail, resulting in data loss.
To avoid this problem, mirror a new, good logical drive to the critical one. When the
Function
Description
Use free Logical
Drive space
Conversion of free space on the logical drives into a separate host
drive.
Change RAID
Type
Migration of the RAID level of an array drive.
RAID 0 to RAID 4 and vice versa
RAID 0 to RAID 5 and vice versa
Add hard disk to
array
Expansion of the capacity of an array drive.
Содержание 2074700-R - ICP Vortex GDT8514RZ RAID Controller
Страница 1: ...Preliminary ICP RAID Software Software Installation and User s Guide Version 1 2 7 June 2003 ...
Страница 23: ...Software Installation and User s Guide 23 Introduction ...
Страница 68: ...68 Software Installation and User s Guide Installing Linux ...
Страница 92: ...92 Software Installation and User s Guide Installing Berkeley UNIX FreeBSD ...
Страница 214: ...214 Software Installation and User s Guide Fibre Channel Features ...