background image

     

 

 

 

 

 

© Adam Equipment Company 2011

 

 

 

Adam Equipment 

 
 
 
 

 

 

 

ABK, AFK Scales 

 
 
 

(P.N. 3116611364 - Revision A, December 2011) 

 

This Document is Hosted by: www.oldwillknottscales.com

Содержание ABK 120

Страница 1: ...Adam Equipment Company 2011 Adam Equipment ABK AFK Scales P N 3116611364 Revision A December 2011 This Document is Hosted by www oldwillknottscales com...

Страница 2: ...am Equipment Company 2011 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and pl...

Страница 3: ...25 7 4 SCALE PARAMETERS 26 8 0 BATTERY OPERATION 28 9 0 RS 232 INTERFACE 29 9 1 INPUT COMMANDS FORMAT 32 10 0 RELAY INTERFACE 33 11 0 CALIBRATION 35 12 0 SERVICE SECTION 36 12 1 USING 1000 TO ENTER TH...

Страница 4: ...2 P a g e Adam Equipment Company 2011...

Страница 5: ...mit next to the display These can work in conjunction with an audible alarm for check weighing as well as LCD showing LO OK and HI The ABK AFK is supplied with a RS 232 bi directional interface and re...

Страница 6: ...2lb Eccentric Loading 0 4g 0 001lb 1g 0 002lb 2g 0 004lb 4g 0 01lb 10g 0 02lb Pan size w x d 300 mm x 400mm Units of Measure g Kg Lb Lb oz Newtons Ounces for all non approved Stabilization Time 2 3 Se...

Страница 7: ...mm x 500mm Units of Measure g Kg Lb Lb oz Newtons Ounces for all non approved Stabilization Time 2 3 Secs Operating Temperature 10 C to 40 C 32 F to 104 F Power Supply 6v 4 5Ah battery 12vDC 800mA Ext...

Страница 8: ...ce in direct sunlight or near air conditioning vents Avoid unsuitable tables The table or floor must be rigid and not vibrate Avoid unstable power sources Do not use near large users of electricity su...

Страница 9: ...thin the tube The ABK AFK Series comes with a stainless steel platform packed separately Place the platform in the base Level the scale by adjusting the four feet If the scale rocks re adjust the feet...

Страница 10: ...sults A secondary function is of Enter key used when setting up the value for the Parameters Pcs Selects parts counting Used to set the sample quantities while parts counting A secondary function is o...

Страница 11: ...values for Parameters Print M Esc Sends the results to a PC or a Printer using the RS 232 interface It also adds the value to the accumulation memory if the accumulation function is not automatic A s...

Страница 12: ...LED s above the display will show when a weight is below or above check weighing limits Other symbols will show when a weight has been tared NET the scale is at zero and stable if a value has been sto...

Страница 13: ...show an indicator for zero The scale has an automatic re zeroing function to account for minor drifting or accumulation of material on the platform However you may need to press the Z T key to rezero...

Страница 14: ...taring will be displayed When the container is removed a negative value will be shown If the scale was tared just before removing the container this value is the gross weight of the container plus all...

Страница 15: ...r 200 pieces When the scale is showing weight pressing the Pcs key will start the parts counting function The scale will show P 10 asking for a sample size of 10 parts Change the sample size to the de...

Страница 16: ...as described below See Section 7 1 for the procedure to set the limits The limits can be set when the scale is in weighing or parts counting modes After limits have been set the Check weighing functi...

Страница 17: ...ll be off when the weight is less than the Low Limit Above the Low Limit the beeper will be on F3 bEP bP OtL The beeper will be on sound when the weight is below the Low Limit HIGH LIMIT SET LOW LIMIT...

Страница 18: ...d in kg or Lb or pcs respectively Checkweighing during Parts Counting To disable the Check Weighing function enter zero into both limits by pressing the Func C key when the current limits values are d...

Страница 19: ...ry the display will show ACC 1 and then the total in memory for 2 seconds before returning to weighing The RS 232 interface will output to a printer or PC Remove the weight allowing the scale to retur...

Страница 20: ...display FunC 2 Press the Z T key P1 PCt will be displayed Press Z T again to enter percent weighing The scale will set the sample mass on the platform as 100 reference weight Remove the sample weight...

Страница 21: ...layed Press Z T again to enter percent weighing The scale will now accept a value the user enters as the reference weight Enter the value using the Unit key and Pcs key to set the values of the 100 ma...

Страница 22: ...ond function P2 AnL Animal weighing Press Z T to enter animal weighing The scale will change to animal weighing and allow weighing of an unstable animal or sample on the platform To use the Animal Wei...

Страница 23: ...nimal Dynamic weighing symbol until a stable weight is determined The time it takes for the stable value will depend upon the setting of the filter parameter in the first step When a stable reading is...

Страница 24: ...ps FunC 1 FunC 2 FunC 3 and FunC 4 Press Z T to enter the desired group of parameters When in one of the sections press Print M Esc to return to the group FunC 1 If you press Print M Esc again the sca...

Страница 25: ...beeper can further be set to sound when the weighing result is within or outside the check weighing limits bP oFF Off bP inL Within limits bP otL Outside limits 20d bP inL F4 nCK This parameter enabl...

Страница 26: ...s Press Z T to confirm the change and then advance to the next parameter by pressing the Pcs key Press Print M Esc to return to Pcs the group FUnC 3 If you press Print M Esc again the scale will exit...

Страница 27: ...key pressed If Print M Esc is pressed a second time only print the weight Print when Print M Esc key is pressed Do not accumulate Cont Not available on approved scales Print continuously Accumulate w...

Страница 28: ...oFF EL on EL AU EL AU S3 AoF Auto Off Disable or set time increment to turn off scale SLP 0 SLP 1 SLP 5 SLP 10 SLP 0 S4 dt Set Time and Date format and settings Format for date can be changed when the...

Страница 29: ...e been turned off the scale will still operate for a short time after which it will automatically switch off to protect the battery To charge the battery simply plug the adaptor into the mains power T...

Страница 30: ...ed weighing unit through the RS 232 interface Specifications RS 232 serial interface is a plug as figure 2 shows 1 Pin GND Signal Ground 2 Pin RXD Received Data 3 Pin TXD Transmitted Data As viewed fr...

Страница 31: ...ts are printed cr lf cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf Net Wt 1 234 Kg cr lf Net Wt or Gross Wt Unit Wt 123 g cr lf g for metric an...

Страница 32: ...In other languages the format is the same but the text will be in the language selected cr lf Date 12 09 2006 cr lf Time 14 56 27 cr lf cr lf Scale ID 123456 cr lf User ID 234567 cr lf cr lf cr lf TOT...

Страница 33: ...Heure Zeit Hora Scale ID number Scale ID Bal ID Waagen ID Bal ID User ID Number User ID Util ID Nutzer ID Usuario ID 9 1 INPUT COMMANDS FORMAT The scale can be controlled with the following commands P...

Страница 34: ...lowing conditions apply CONNECTION OF RELAY DRIVERS The output to drive external relays is on the circuit board inside the enclosure To gain access you must remove the 6 screws securing the front to t...

Страница 35: ...ly press on the top of the connector and insert the wire Do not exceed the safe limits of voltage or current of 24VDC or 15ma per output Depending upon the application it may be necessary to use a sma...

Страница 36: ...move any weight from platform when the stable symbol is on press Z T The display will show Ld the 0000XX to show the last calibration weight used Place this calibration weight on the scale Press the Z...

Страница 37: ...2006 will allow access to all parameters as shown in section 12 3 12 1 USING 1000 TO ENTER THE SERVICE PARAMETERS Press the Z T key during the display counting when turned on When Pn is displayed ent...

Страница 38: ...s will show the first parameters called F1 CAL To select another parameter press the Pcs key to advance through the parameters Press the Z T key to enter a parameter To exit a parameter press the Prin...

Страница 39: ...ecessary change the value shown to match the weight to be used Press CE to clear the old value and then enter the new value All values entered are in whole numbers only Add the weight shown wait for s...

Страница 40: ...flashing either kilogram kg or pounds lb Press Z T to accept the displayed value On non approved versions the display then lets you select the increment InC 2 For example 100kg x 0 01kg the increment...

Страница 41: ...r off Press the Pcs key to change the value Press Z T to accept the displayed value Press Print M Esc to return to weighing 12 3 7 F7 ADC COUNTS To enter this parameter press the Z T key when F7 Cnt i...

Страница 42: ...display will show if the current Auto Zero range Press the Pcs key to change the value Press Z T to accept the displayed value Press Print M Esc to return to weighing 12 3 11 Fb FPS User Function Pas...

Страница 43: ...Z T key to set the display to zero value If the problem persists contact your dealer or Adam Equipment for assistance Err 6 A D out of range The values from the A D converter are outside the normal ra...

Страница 44: ...ept ready A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should always...

Страница 45: ...ginal packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performa...

Страница 46: ...45 P a g e Adam Equipment Company 2011...

Страница 47: ...n a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with t...

Страница 48: ...sion of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publ...

Отзывы: