Rev. 1
HEXAPAD 10 BC USB
8.8 Increasing rejection of side readings
To obtain a reading field as close as possible to the figure above, the RSSI reading filter should be used
in conjunction with the reading power setting. With these adjustment plus the integrated near field
antenna the rejection of side readings greatly increases.
8.8.1 How to measure the RSSI cutoff value?
The cut-off value of the tag reading signal level should be obtained in a practical manner, that is, with
the tags that will be used in the application and reading tests checking the rssi value reported on the
sides and on top of the reader.
In order to facilitate the execution of rssi level readings, the repetition rate of reading of the
NOTE:
Tags can be increased as described in "
8.5 Reading rate of the same tag"
To obtain the RSSI value of each read you take, use the "
reportrssi on"
command.
NOTE:
To configure the reader to report readings only above an RSSI value, use the
command "
rssifilter xx
", where xx is the desired value.
Содержание HEXAPAD 10
Страница 5: ...Rev 1 HEXAPAD 10 BC USB BLANK...
Страница 14: ...Rev 1 HEXAPAD 10 BC USB Part 1 Overview and installation Equipment Overview Installation...
Страница 15: ...Rev 1 HEXAPAD 10 BC USB 6 Equipment overview 6 1 Hardware HEXAPAD...
Страница 17: ...Rev 1 HEXAPAD 10 BC USB 6 2 1 Barcode reading angulation Field Vision Field Vision...
Страница 19: ...Rev 1 HEXAPAD 10 BC USB 2 Big carcode Barcode placement...
Страница 23: ...Rev 1 HEXAPAD 10 BC USB 6 2 1 3 VSWR integrated antenna 6 2 1 4 Gain Far Field...
Страница 27: ...Rev 1 HEXAPAD 10 BC USB 7 1 1 1 2 Step 2 Load the driver 1 Right click go to Update Driver...
Страница 33: ...Rev 1 HEXAPAD 10 BC USB Part 2 Standalone Mode Reader in Standalone Mode Reader Settings Usage Examples...
Страница 80: ...Rev 1 HEXAPAD 10 BC USB...
Страница 83: ...Rev 1 HEXAPAD 10 BC USB 10 Part 4 Update the firmware How to update the firmware of the reader Windows...
Страница 85: ...Rev 1 HEXAPAD 10 BC USB 4 Type help without argument to verify that the reader is connected correctly...