Rev. 1
HEXAPAD 10 BC USB
8.5.4.4 rfon - Reading time
Command
rfon value
Function
Check (no value) or change the read time in ms (milliseconds).
Description
The reading time is equivalent to the time when the reader transmits RF power to its
antenna in an attempt to read a tag. When you have too many tags to read at the same
time, the reading time should be increased.
Pattern
250 ms
Values
50 .. 5000
Example
To check the reading time:
rfon<CR>
250<CR>
To change the reading time to 500 ms (0.5 s):
500<CR rfon>
ok - parameter has been changed.<CR>
Errors
When the value reported is not among the specified:
error - value out of range<CR>
When more than one value is passed to the command:
error - too many args.<CR>
NOTE:
If the application requires reading multiple tags at the same time, leave the
rfon above 250ms to give time to energize all tags in the reader field.
NOTE:
The
reading results are reported by the reader after the sum of rfon rfoff times.
Содержание HEXAPAD 10
Страница 5: ...Rev 1 HEXAPAD 10 BC USB BLANK...
Страница 14: ...Rev 1 HEXAPAD 10 BC USB Part 1 Overview and installation Equipment Overview Installation...
Страница 15: ...Rev 1 HEXAPAD 10 BC USB 6 Equipment overview 6 1 Hardware HEXAPAD...
Страница 17: ...Rev 1 HEXAPAD 10 BC USB 6 2 1 Barcode reading angulation Field Vision Field Vision...
Страница 19: ...Rev 1 HEXAPAD 10 BC USB 2 Big carcode Barcode placement...
Страница 23: ...Rev 1 HEXAPAD 10 BC USB 6 2 1 3 VSWR integrated antenna 6 2 1 4 Gain Far Field...
Страница 27: ...Rev 1 HEXAPAD 10 BC USB 7 1 1 1 2 Step 2 Load the driver 1 Right click go to Update Driver...
Страница 33: ...Rev 1 HEXAPAD 10 BC USB Part 2 Standalone Mode Reader in Standalone Mode Reader Settings Usage Examples...
Страница 80: ...Rev 1 HEXAPAD 10 BC USB...
Страница 83: ...Rev 1 HEXAPAD 10 BC USB 10 Part 4 Update the firmware How to update the firmware of the reader Windows...
Страница 85: ...Rev 1 HEXAPAD 10 BC USB 4 Type help without argument to verify that the reader is connected correctly...