Rev. 1
HEXAPAD 10 BC USB
8.5.4.7 gen2tari - EPC Gen2 Tari pulse time
Command
gen2tari value
Function
Check (no value) or change the "Tari" parameter of the Gen2 pattern.
Description
The Tari is time in us (microseconds) of the pulse of each bit transmitted by the tag.
Pattern
25 U.S.
Values
6.25
12.5
25
Notes
Values 12.5 us and 25 us can only be set if the gen2blf is set to 250 KHz.
The values 6.25 us and 12.5 us are supported only by the internal RF module
micro-module type, which can be checked by rfidmodule command.
Example
To check the Tari value:
gen2tari<CR>
25<CR>
To change the value of Tari to 12.5 us:
gen2tari 12.5<CR>
ok - parameter has been changed.<CR>
Errors
When the value reported is not among the specified:
error - value out of range<CR>
When more than one value is passed to the command:
error - too many args.<CR>
When a value not supported by the RF module is passed:
error - value not supported for this RF Module.<CR>
When a value not supported by the already configured BLF is passed:
error - gen2 wrong parameters combination.<CR>
Содержание HEXAPAD 10
Страница 5: ...Rev 1 HEXAPAD 10 BC USB BLANK...
Страница 14: ...Rev 1 HEXAPAD 10 BC USB Part 1 Overview and installation Equipment Overview Installation...
Страница 15: ...Rev 1 HEXAPAD 10 BC USB 6 Equipment overview 6 1 Hardware HEXAPAD...
Страница 17: ...Rev 1 HEXAPAD 10 BC USB 6 2 1 Barcode reading angulation Field Vision Field Vision...
Страница 19: ...Rev 1 HEXAPAD 10 BC USB 2 Big carcode Barcode placement...
Страница 23: ...Rev 1 HEXAPAD 10 BC USB 6 2 1 3 VSWR integrated antenna 6 2 1 4 Gain Far Field...
Страница 27: ...Rev 1 HEXAPAD 10 BC USB 7 1 1 1 2 Step 2 Load the driver 1 Right click go to Update Driver...
Страница 33: ...Rev 1 HEXAPAD 10 BC USB Part 2 Standalone Mode Reader in Standalone Mode Reader Settings Usage Examples...
Страница 80: ...Rev 1 HEXAPAD 10 BC USB...
Страница 83: ...Rev 1 HEXAPAD 10 BC USB 10 Part 4 Update the firmware How to update the firmware of the reader Windows...
Страница 85: ...Rev 1 HEXAPAD 10 BC USB 4 Type help without argument to verify that the reader is connected correctly...