Rev. 1
HEXAPAD 10 BC USB
8.5.4.6 gen2blf - EPC Gen2 Backscatter Frequency Link
Command
gen2blf value
Function
Check (no value) or change the "Backscatter Link Frequency" parameter of the Gen2
pattern.
Description
Blf is the data rate in KHz of transmission by air between a tag and the reader.
Pattern
250 Khz
Values
250
320
640
Notes
By changing the BLF to 640 or 320 KHz, the tari value and tag encoding will automatically
change to 6.25 us and fm0 respectively.
Example
To check the BLF value:
gen2blf<CR>
250<CR>
To change the BLF value to 640 KHz:
640<CR gen2blf>
ok - parameter has been changed.<CR>
Errors
When the value reported is not among the specified:
error - value out of range<CR>
When more than one value is passed to the command:
error - too many args.<CR>
AVISO:
Changing the gen2blf will imply automatic change by the reader of
another EPC gen2 parameters, which are gen2tari and
gen2tagencolding
Содержание HEXAPAD 10
Страница 5: ...Rev 1 HEXAPAD 10 BC USB BLANK...
Страница 14: ...Rev 1 HEXAPAD 10 BC USB Part 1 Overview and installation Equipment Overview Installation...
Страница 15: ...Rev 1 HEXAPAD 10 BC USB 6 Equipment overview 6 1 Hardware HEXAPAD...
Страница 17: ...Rev 1 HEXAPAD 10 BC USB 6 2 1 Barcode reading angulation Field Vision Field Vision...
Страница 19: ...Rev 1 HEXAPAD 10 BC USB 2 Big carcode Barcode placement...
Страница 23: ...Rev 1 HEXAPAD 10 BC USB 6 2 1 3 VSWR integrated antenna 6 2 1 4 Gain Far Field...
Страница 27: ...Rev 1 HEXAPAD 10 BC USB 7 1 1 1 2 Step 2 Load the driver 1 Right click go to Update Driver...
Страница 33: ...Rev 1 HEXAPAD 10 BC USB Part 2 Standalone Mode Reader in Standalone Mode Reader Settings Usage Examples...
Страница 80: ...Rev 1 HEXAPAD 10 BC USB...
Страница 83: ...Rev 1 HEXAPAD 10 BC USB 10 Part 4 Update the firmware How to update the firmware of the reader Windows...
Страница 85: ...Rev 1 HEXAPAD 10 BC USB 4 Type help without argument to verify that the reader is connected correctly...