9
CHANGING THE ACTIVEPURE
®
CELL
1 Disconnect (unplug) power
cord from unit
2 Remove the (4) thumb nuts
3 Remove the unit from the
mounting plate
Power Cord
5 Remove the used
ActivePure Cell from the base unit
and dispose of the bulb properly
4 Remove the two thumb
screws holding the ActivePure
Cell
6 Plug the new ActivePure Cell into
the base unit Be sure Air Flow
/ Honeycomb Cell direction is
correct
WARNING
• UV Light in operation; disconnect unit from power cord before servicing;
failure to follow warnings may result in severe eye damage
• If the unit is hard wired, be sure the power to the unit is off; always follow OHSA
electrical lockout safety requirements to prevent accidental release of energy
during service or maintenance activities
7 Secure with (2)thumb
screws
8 Insert the unit into the