Installing the System
Installation Overview
Mounting the ML600
The ML600 unit can be mounted in the following ways:
one or two units in 1U x 19” rack mount sleeve mounted in 19” (482 mm), 23” (584 mm)
or ETSI racks;
on a horizontal surface (desktop);
on a wall.
Rack Mounting
For 19”/23”/ETSI racks
: For rack mount use the rack mount sleeve. See “Appendix B -
Parts List” in the
ML600 User Manual
for list of parts. The following figure presents the
installation of brackets for mount option.
The mounting brackets for 19” and 23” racks can be positioned so that their flanges are flush
with the front of the unit or offset by 5” (127 mm). In the following figure, the 19” bracket is
shown flush, the 23” bracket is shown offset by 5” and the ETSI bracket is shown with offset
of 40 mm.
Figure 2: Methods for attaching rack mounting brackets
Note: Since primary airflow and cooling for the ML600 unit occurs through the front and rear
of the unit, it is acceptable to stack multiple unit on top of one another in a standard
equipment rack, without leaving airspace between the units.
8 ML600 Release 5.0
a
Quick Installation Guide