SERIES IP1K100 INDUSTRIAL I/O PACK RECONFIGURABLE DIGITAL I/O MODULE
___________________________________________________________________________________________
- 4 -
IP MODULE ActiveX CONTROL SOFTWARE
Acromag provides a software product (sold separately)
consisting of IP module ActiveX (OLE) controls for Windows 98,
95
, ME, 2000, XP and Windows NT
compatible application
programs (Model IPSW-ATX-PCI, MSDOS format). This software
provides individual controls that allow Acromag IP modules to be
easily integrated into Windows
application programs, such as
Visual C++
, Visual Basic
, Microsoft
Office
97 applications
and others. The ActiveX controls provide a high-level interface to IP
modules, eliminating the need to perform low-level reads/writes of
registers, and the writing of interrupt handlers—all the complicated
details of programming are handled by the ActiveX controls. The
ActiveX control IP1K100 support programs implement the transfer of
developed code between the user’s processor and the Altera FPGA.
These functions are intended for use in conjunction with an
Acromag personal computer carrier and consist of an ActiveX
Carrier Control, and an ActiveX control for each Acromag IP module,
as well as, a generic control for non-Acromag IP modules.
IP MODULE VxWORKS SOFTWARE
Acromag provides a software product (sold separately)
consisting of IP module VxWorks
libraries. This software (Model
IPSW-API-VXW MSDOS format) is composed of VxWorks
(real
time operating system) libraries for all Acromag IP modules and
carriers including the AVME9670, AVME9660/9630, APC8620/21,
ACPC8630/35, and ACPC8625. The software is implemented as a
library of “C” functions which link with existing user code to make
possible simple control of all Acromag IP modules and carriers. The
IP1K100 support programs implement the transfer of developed
code between the user’s processor and the Altera FPGA.
2.0 PREPARATION FOR USE
UNPACKING AND INSPECTION
Upon receipt of this product, inspect the shipping carton for
evidence of mishandling during transit. If the shipping carton is
badly damaged or water stained, request that the carrier's agent be
present when the carton is opened. If the carrier's agent is absent
when the carton is opened and the contents of the carton are
damaged, keep the carton and packing material for the agent's
inspection.
For repairs to a product damaged in shipment, refer to the
Acromag Service Policy to obtain return instructions. It is
suggested that salvageable shipping cartons and packing material
be saved for future use in the event the product must be shipped.
This board is physically protected with
packing material and electrically
protected with an anti static bag during
shipment. However, it is recommended
that the board be visually inspected for
evidence of mishandling prior to
applying power.
The board utilizes static sensitive
components and should only be
handled at a static-safe workstation.
CARD CAGE CONSIDERATIONS
Refer to the specifications for loading and power requirements.
Be sure that the system power supplies are able to accommodate
the power requirements of the carrier board, plus the installed IP
modules, within the voltage tolerances specified.
IMPORTANT: Adequate air circulation must be provided to prevent
a temperature rise above the maximum operating temperature.
The dense packing of the IP modules to the carrier board
restricts air flow within the card cage and is cause for concern.
Adequate air circulation must be provided to prevent a temperature
rise above the maximum operating temperature and to prolong the
life of the electronics. If the installation is in an industrial
environment and the board is exposed to environmental air, careful
consideration should be given to air-filtering.
BOARD CONFIGURATION
Power should be removed from the board when installing IP
modules, cables, termination panels, and field wiring. Refer to
Mechanical Assembly Drawing 4501-434 and the following
discussion for configuration and assembly instructions. Model
IP1K100 I/O Boards have no jumpers or switches to configure—all
configuration is through software commands.
CONNECTORS
IP Field I/O Connector (P2)
P2 provides the field I/O interface connector for mating IP
modules to the carrier board. P2 is a 50-pin female receptacle
header (AMP 173279-3 or equivalent) which mates to the male
connector of the carrier board (AMP 173280-3 or equivalent). This
provides excellent connection integrity and utilizes gold-plating in the
mating area. Threaded metric M2 screws and spacers are supplied
with the module to provide additional stability for harsh environments
(see Mechanical Assembly Drawing 4501-434). The field and logic
side connectors are keyed to avoid incorrect assembly.
P2 pin assignments are unique to each IP model (see Table 2.1)
and normally correspond to the pin numbers of the field-I/O interface
connector on the carrier board (you should verify this for your carrier
board). When reading Table 2.1 notice that RS485 input/output
channels as well as digital TTL input/output channels are listed with
their corresponding connector pin number. Each I/O point will be
either RS485 or TTL defined by your IP1K100 model. Table 2.2
lists the channels dedicated to each of the IP1K100 models.