SERIES IP1K100 INDUSTRIAL I/O PACK                                        RECONFIGURABLE DIGITAL I/O MODULE
___________________________________________________________________________________________

- 14 -

Fail-Safe Operation

The IP1K100 operation is considered ‘Fail-safe’.  That is, the

input/output channels are always configured as input upon power-up
reset, and a system software reset.  This is done for safety reasons
to ensure reliable control of the output state under all conditions.

Digital I/O Interface

The IP1K100 allows interface with a mix of up to 48 TTL I/O

channel or up to 24 differential I/O signals.  The signals DIO0 to
DIO47 are utilized for digital input/output control to the field signals.
The six signals DIFF_DIR(1-6), given in Table 4.1, control data
direction of the 24 differential I/O signals.  The six signals
TTL_DIR(1-6) control data direction of the 48 TTL I/O channels.

EIA-RS485 AND RS422 SERIAL INTERFACE

The EIA-RS485 and RS422 interface specifies a balanced

driver with balanced receivers.  Balanced data transmission refers to
the fact that two conductors are switched per signal and the logical
state of the data is referenced by the difference in potential between
the two conductors, not with respect to signal ground.  The
differential method of data transmission makes EIA-RS485 and
RS422 ideal for noisy environments since it minimizes the effects of
coupled noise and ground potential differences.  That is, since these
effects are seen as common-mode voltages (common to both lines),
not differential, they are rejected by the receivers.

The EIA-RS422 standard defines a bus with a single driver and

multiple receivers.

The EIA-RS485 standard defines a bi-directional, terminated,

driver and receiver configuration.  Half-duplex operation is mandated
by the sharing of a single data path for transmit and receive.  The
maximum data transmission cable length is generally limited to 4000
feet without a signal repeater installed.

With respect to EIA-RS485 and RS422, logic states are

represented by differential voltages from 1.5 to 5V.  The polarity of
the differential voltage determines the logical state.  A logic “0” is
represented by a negative differential voltage between the terminals
(measured A to B, or + to -).  A logic “1” is represented by a positive
differential voltage between the terminals (measured A to B, or + to -
).  The line receivers convert these signals to the conventional TTL
level.

Memory Interface

The IP1K100 interfaces to a 64K word SRAM device.  This

memory interface utilizes the address signals RAMa1 to RAMa16,
data signals RAMd0 to RAMd15, and the read/write control signals
nWE_RAM, nBLE_RAM, nBHE_RAM, and nOE_RAM as listed in
Table 4.1.  The RAM device is the Integrated Device Technology
IDT71016 or the Cypress Cy7C1021.

IP Bus Interface

The IP1K100 interfaces to the carrier board per IP Module

specification ANSI/VITA 4 1995.  The FPGA signals utilized are: 16
data lines (DATA0 to DATA15), and six address lines A(1 to 6).
The many control lines that comprise the IP bus include: IP Reset,
nIOsel, nIDsel, nMEMsel, nINTsel, R_nW, nAck, nIntReq0,
nIntReq1, nDMAReq0, nDMAReq1, nDMAck, nDMAend, nStrobe,

nBS0, and nBS1.  Table 4.1 lists the FPGA pins corresponding to
these signals.  The IP bus 8MHz clock signal is present on pin IP
CLK.  The function and timing requirements of all IP bus signals are
specified in the ANSI/VITA 4 1995 specification.  Copies of the
ANSI/VITA 4 1995 specification are available from VITA
(www.vita.com).

Clock Generator Interface

A clock generator chip (Cypress ICD2053) is available to

provide a user programmable clock frequency between 391KHz and
100MHz.  A total of four signals are utilized: Ref Clock, SCLK,
SDATA, and Gen Clock as seen in Table 4.1.

Signal

Description

Ref Clock

The Ref Clock or reference clock is a 4MHz
clock generated by the FPGA from the IP bus
8MHz clock signal.

SCLK

This is the serial clock to the ICD2053.  It is
used for clock frequency programming.

SDATA

The serial data is sent from the FPGA to the
ICD2053 on this pin for clock frequency
programming.

Gen Clock

The clock frequency generated by the
ICD2053 is input to the FPGA on this pin.

Initialization Interface

The configuration method used by the IP1K100 is the Altera

passive parallel asynchronous.  The initialization interface utilizes
eight signals. nConfig, Conf_Done, RDYnBUSY, Init_Done,
nStatus, nWS, CS, and nCS.  The function and timing requirements
of these signals are defined by the Altera Configuring Devices
Application Note 116.  A copy of the Configuring Devices Application
note 116 is available from Altera (www.altera.com).

SIGNAL PIN ASSIGNMENTS

The signal pin assignments for the IP1K100 are listed in table

4.1.  The pin assignments shown must be fixed in your Altera ACF
file.  An example ACF file is provided with the design files that
accompany the IP1K100 EDK.

Table 4.1: Altera FPGA Pin Assignments
Pin

Signal

I/O

1

TCK

Input (Pull-Down)

2

Conf_Done

Output (2 CPLD)

3

nCEO

Output (Unconnect)

4

TDO

Output (Unconnect)

5

VCCIO

3.3Volts

6

GND

GND

7

RAMa1

Output

8

RAMa2

Output

9

RAMa3

Output

10

CLKUSR

Input (Pulled High)

11

RAMa4

Output

12

RAMa5

Output

13

RAMa6

Output

14

RAMa7

Output

15

RAMa8

Output

16

RDYnBUSY

Output (To CPLD)

17

RAMa9

Output

18

RAMa10

Output

Содержание IP1K100 Series

Страница 1: ...ard USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 2001 Acromag Inc Printed in the USA Data and specifications are subject to change without notice 8500 681 B02H012 retired ...

Страница 2: ...PAIR ASSISTANCE 16 PRELIMINARY SERVICE PROCEDURE 16 6 0 SPECIFICATIONS 16 PHYSICAL 16 ENVIRONMENTAL 16 EIA RS485 RS422 TRANSCEIVERS 17 TTL TRANSCEIVERS 17 INDUSTRIAL I O PACK COMPLIANCE 17 APPENDIX 18 CABLE MODEL 5025 551 18 CABLE MODEL 5025 552 18 TRANSITION MODULE MODEL TRANS GP 18 DRAWINGS Page 4501 908 IP1K100 BLOCK DIAGRAM 19 4501 702 RS485 I O CONNECTIONS 20 4501 434 IP MECHANICAL ASSEMBLY 2...

Страница 3: ...as its own 8 bit ID information which is accessed via data transfers in the ID Read space 16 bit 8 bit I O Channel register Read Write is performed through D16 or D08 EO data transfer cycles in the IP module I O space High Speed Access times for all data transfer cycles are described in terms of wait states For the supplied IP module example wait states are utilized for all read and write operatio...

Страница 4: ...for future use in the event the product must be shipped This board is physically protected with packing material and electrically protected with an anti static bag during shipment However it is recommended that the board be visually inspected for evidence of mishandling prior to applying power The board utilizes static sensitive components and should only be handled at a static safe workstation CA...

Страница 5: ...y limited to less than 4000 feet To minimize transmission line problems all nodes connected to the cable must use minimum stub length connections The optimal configuration for the RS485 RS422 bus is a daisy chain connection from node 1 to node 2 to node 3 to node n The bus must form a single continuous path and the nodes in the middle of the bus must not be at the ends of long branches spokes or s...

Страница 6: ...nd configuration is implemented with no special hardware or cables An example program written in C is available from Acromag ActiveX Control or VxWorks software implements configuration of the IP1K100 over the IP bus The program requires your configuration file to be in the Intel Hex format Using the Altera MAX PLUS II software you can generate the required hex file as follows 1 In the MAX PLUS II...

Страница 7: ...rmation required for the module The IP1K100 ID space does not contain any variable e g unique calibration information ID space bytes are addressed using only the odd addresses in a 64 byte block on the Big Endian VMEbus Even addresses are used on the Little Endian PC ISA or PCI buses The IP1K100 ID space will read differently in configuration mode than it does in user mode In configuration mode th...

Страница 8: ...ormat Big Endian is the convention used in the Motorola 68000 and PowerPC microprocessor family and is the VMEbus convention In Big Endian the lower order byte is stored at odd byte addresses The Intel x86 family of microprocessors uses the opposite convention or Little Endian byte ordering Little Endian uses even byte addresses to store the low order byte As such use of the memory map for this mo...

Страница 9: ...f 8 channels Setting a bit high configures the data direction for the identified channels as output Setting the control bit low configures the corresponding channel s data direction for input The default power up state of these registers is logic low Thus all channels are configured as inputs on system reset or power up The unused upper nibble D15 to D12 of the register at base address 08H will al...

Страница 10: ...ata Bit 01 Data Bit 00 Ch07 Ch06 Ch05 Ch04 Ch03 Ch02 Ch01 Ch00 The unused upper 8 bits of this register are Not Used and will always read low 0 s for D16 accesses All bits are set to 0 following a reset which means that all interrupts are cleared Interrupt Polarity Registers Read Write Base 11H The Interrupt Polarity Register determines the level that will cause a channel interrupt to occur for ea...

Страница 11: ...h and Low registers This Length value is used by the hardware to set the number of clock cycles the Shift High and Shift Low values are shifted to the Clock Generator chip See the program procedure example which follows for information on determining the value to write to this register A write access to this register requires one wait state A software or hardware reset will clear the contents of t...

Страница 12: ...interrupts input channel bandwidth should be limited to reduce the possibility of missing channel interrupts For a given input channel this could happen if multiple changes occur before the channel s interrupt is serviced The response time of the input channels should also be considered when calculating this bandwidth The total response time is the sum of the input buffer response time plus the in...

Страница 13: ...own in Drawing 4501 908 as you review this material FIELD INPUT OUTPUT SIGNALS The field I O interface to the IP module is provided through connector P2 refer to Table 2 1 These pins are tied to the inputs and outputs of EIA RS485 RS422 line transceivers or TTL transceivers RS485 signals received are converted from the required EIA RS485 RS422 voltages signals to the TTL levels required by the FPG...

Страница 14: ...he address signals RAMa1 to RAMa16 data signals RAMd0 to RAMd15 and the read write control signals nWE_RAM nBLE_RAM nBHE_RAM and nOE_RAM as listed in Table 4 1 The RAM device is the Integrated Device Technology IDT71016 or the Cypress Cy7C1021 IP Bus Interface The IP1K100 interfaces to the carrier board per IP Module specification ANSI VITA 4 1995 The FPGA signals utilized are 16 data lines DATA0 ...

Страница 15: ... 76 GND GND 77 VCC_CKLK 2 5Volts 78 nBS0 Input IP Bus 79 IP CLK GCLK1 IP Module Clock 80 nBS1 Input IP Bus 81 GND_CKLK GND Pin Signal I O 82 GND GND 83 DIO12 Bi Dir 84 VCCIO 3 3Volts 85 DIO13 Bi Dir 86 DIO14 Bi Dir 87 DIO15 Bi Dir 88 DIO16 Bi Dir 89 DIO17 Bi Dir 90 DIO18 Bi Dir 91 VCCINT 2 5Volts 92 DIO19 Bi Dir 93 DIO20 Bi Dir 94 DIO21 Bi Dir 95 DIO22 Bi Dir 96 DIO23 Bi Dir 97 DIO24 Bi Dir 98 VCC...

Страница 16: ... REPAIR ASSISTANCE Surface Mounted Technology SMT boards are generally difficult to repair It is highly recommended that a non functioning board be returned to Acromag for repair The board can be easily damaged unless special SMT repair and service tools are used Further Acromag has automated test equipment that thoroughly checks the performance of each board When a board is first produced and whe...

Страница 17: ...rrent 250mA Maximum Input Hysteresis 70mV VCM 0V TTL TRANSCEIVERS Channel Configuration Up to 48 non isolated TTL signals Selected in blocks of 8 channels when ordered Integrated Circuit Device Pericom PI74FCT623T http www pericom com INDUSTRIAL I O PACK COMPLIANCE Specification This device meets or exceeds all written Industrial I O Pack specifications per ANSI VITA 4 1995 for 8MHz or 32MHz opera...

Страница 18: ... Pack modules Field signals are accessed via screw terminal strips The terminal strip markings on the termination panel 1 50 correspond to P2 pins 1 50 on the Industrial I O Pack IP Each Industrial I O Pack IP has its own unique P2 pin assignments Refer to the IP module manual for correct wiring connections to the termination panel Schematic and Physical Attributes See Drawing 4501 464 Field Wirin...

Страница 19: ...SERIES IP1K100 INDUSTRIAL I O PACK RECONFIGURABLE DIGITAL I O MODULE ___________________________________________________________________________________________ 19 ...

Страница 20: ...SERIES IP1K100 INDUSTRIAL I O PACK RECONFIGURABLE DIGITAL I O MODULE ___________________________________________________________________________________________ 20 ...

Страница 21: ...SERIES IP1K100 INDUSTRIAL I O PACK RECONFIGURABLE DIGITAL I O MODULE ___________________________________________________________________________________________ 21 ...

Страница 22: ...SERIES IP1K100 INDUSTRIAL I O PACK RECONFIGURABLE DIGITAL I O MODULE ___________________________________________________________________________________________ 22 ...

Страница 23: ...SERIES IP1K100 INDUSTRIAL I O PACK RECONFIGURABLE DIGITAL I O MODULE ___________________________________________________________________________________________ 23 ...

Страница 24: ...SERIES IP1K100 INDUSTRIAL I O PACK RECONFIGURABLE DIGITAL I O MODULE ___________________________________________________________________________________________ 24 4 5 0 1 4 6 4 A ...

Отзывы: