Magnetron TCO
Magnetron TCO
⚠
DANGER
All High Voltage Capacitors must be discharged before performing this procedure.
The Magnetron TCO protects the Magnetron from an overheat situation
Testing
Remove Wires from device
Across Terminals = Continuity @ < 300°F (320°C)
Opens @ 300°F (149°C)
Resets @ 275°F (125°C)
Removal and Replacement
1 Disconnect oven from Power Supply
2 Remove Top and Right or Left Side Panel
(see Panel Removal)
3 Remove Wires from device
4 Remove two (2) Torx-head Screws using a T-15 Driver
5 To replace, reverse these steps
⚠