Part No. 16400033
Original Instructions
Service Test Mode
Service Mode
Purpose
Comments
Oven Information
Provide service provider with
Door Cycles and Magnetron Tube
Hours of operation
Press and the following will display:
Door Cycles:
Tube Hours:
Software Version
Displays the version of software
and firmware installed in the
control
Press and the following will display:
SW:
EE:
App:
Magnetron 1
Right Side
System can be started and
stopped by pressing the Start or
Stop Icon
The current amperage being drawn by the HV system 5 -12 amps
is considered normal Look for consistent reading with Magnetron 2
and Convection Heater This circuit is protected by Fuse F3
Magnetron 2
Left Side
System can be started and
stopped by pressing the Start or
Stop Icon
The current amperage being drawn by the HV system 5 -12 amps
is considered normal Look for consistent reading with Magnetron 1
and Convection Heater This circuit is protected by Fuse F4
Both Magnetrons
Both systems can be started and
stopped by pressing the Start or
Stop Icon
The current amperage being drawn by BOTH HV systems Look for
consistent readings with Convection Heater These are protected by
Fuses F3 & F4
Convection Heater
Heater can be stopped and started
by pressing the Start or Stop Icon
The current amperage being drawn by the Convection Heater 7-15
amps is considered normal This circuit protected by Fuse F5
Radiant Heaters
Not Used for this model
Convection Fan
Low
Convection Fan Motor Low Speed
can be stopped and started by
pressing the Start or Stop Icon
The current amperage being drawn by the Convection Fan Motor
on low speed <2 amps and fan motor operating noise is considered
normal This circuit is protected by Fuse F2
Convection Fan
High
Convection Fan Motor High
Speed can be stopped and
started by pressing the Start or
Stop Icon
The current amperage being drawn by the Convection Fan Motor on
high speed <3 amps and a high speed fan motor operating noise is
considered normal
Cooling Fan
Motors can be stopped and
started by pressing the Start or
Stop Icon
The current amperage being drawn by both the Cooling Fan Motors
1-3 amps is considered normal A failed Cooling Fan motor will likely
result in a G2 Error Code
Antenna Motor
The Antenna Motor can be started
by pressing the Start Icon
NOTE
: The Stop Icon will not stop
the Antenna Motor
USE RADIANT RTD READING ONLY
The Radiant RTD is located between the Magnetrons on top of the
oven To reset maximum temperature reading, press and hold the
Max Radiant RTD for several seconds - temperature will change to
then current temperature sensed
RTD
Resistive Thermal Devices (Temp
Sensors)
Press and the current temperature
sensed by the RTD along with the
maximum temperature recorded
MRX OVENS ONLY HAVE ONE RTD AND MAXIMUM READING
IS NOT USED “NON USED” READING WILL BE 656 or 657 –
USE RADIANT RTD READING ONLY
The Radiant RTD is located at the back center of oven The
Convection RTD is located on the upper left by the Convection
Element To reset maximum temperature reading, press and hold
the Max Convection RTD for several seconds—temperature will
change to the current temperature sensed
Memory
Attached Memory Devices
Press and the following will display:
USB Present or Absent
SD Card Present or Absent
Error History
Chronological List of Errors
experienced by the Control
Press and the following will display:
Error Code Date, Time, and Code (see Error Code List in this section)
Voltage Switching
Displays the voltage as sensed by
the Control
Pressing has no effect.
Temperature Offset
The degree of offset programmed
into Control to synchronize
Control to cavity temperature
Press and the following will display: The amount of temperature
offset programmed by the factory
Pin Code
Displays the 4 Digit Pin Code
Pressing has no effect.
Содержание ARX1
Страница 28: ... 2018 ACP Inc Cedar Rapids IA 52404 Page 28 of 80 Part No 16400033 Original Instructions Care and Cleaning 6 ...
Страница 77: ... 2018 ACP Inc Cedar Rapids IA 52404 Page 77 of 80 Part No 16400033 Original Instructions Notes ...
Страница 78: ... 2018 ACP Inc Cedar Rapids IA 52404 Page 78 of 80 Part No 16400033 Original Instructions Notes ...
Страница 79: ... 2018 ACP Inc Cedar Rapids IA 52404 Page 79 of 80 Part No 16400033 Original Instructions Notes ...
Страница 80: ... 2018 ACP Inc Cedar Rapids IA 52404 Page 80 of 80 Part No 16400033 Original Instructions www acpsolutions com ...