Cooling Fan Relay (24V)
Cooling Fan Relay (24V)
The Cooling Fan Relay is a switching device that controls power to the Cooling Fans
Testing
With oven disconnected from the Power Supply, disconnect the Wires from the device
Check resistance across Coil:
RD to BK
À
550 Ω (3/16” terminals)
Check continuity across contacts:
COM to NC = Continuity
COM to NO = Open
Removal and Replacement
1 Disconnect oven from Power Supply
2 Remove Top, Right, Left and Rear Panels
(see Panel Removal)
3 Note all Wire locations
4 Remove all Wires from the device
5 Remove two (2) Screws securing device
6 To replace, reverse these steps