![ACP ARX1 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/acp/arx1/arx1_service-manual_2840493055.webp)
©2018 ACP, Inc.
Cedar Rapids, IA 52404
Page 55 of 80
Part No. 16400033
Original Instructions
HV Capacitor
HV Capacitor
⚠
DANGER
The high voltages and currents at the filament and secondary winding of the transformer are extremely dangerous.
Never make any direct voltage or current measurements of this component. It is very dangerous to work near this
part when the oven is on, or if this circuitry has been switched off.
⚠
DANGER
All High Voltage Capacitors must be discharged before performing this procedure.
The HV Capacitor is used in the Microwave Circuit to provide the high voltage to supply the Magnetron
Depending on the model, there may be 1 or 2 HV Capacitors
Testing
Capacitance across the Terminals:
0.88μf ±3%
Continuity from each Terminal to the outer case: Open
Removal and Replacement
1 Disconnect oven from Power Supply
2 Remove Top, Right, Left and Rear Panels
(see Panel Removal)
3 Remove Wire from the device(s) noting their positions
4 Using a 1/4” Hex Socket, remove the four (4) Screws
securing the Mounting Crossbar
5 Remove the Screws securing the Capacitor(s) to the
Crossbar
6 To replace, reverse these steps
⚠
DANGER
⚠
DANGER
Содержание ARX1
Страница 28: ... 2018 ACP Inc Cedar Rapids IA 52404 Page 28 of 80 Part No 16400033 Original Instructions Care and Cleaning 6 ...
Страница 77: ... 2018 ACP Inc Cedar Rapids IA 52404 Page 77 of 80 Part No 16400033 Original Instructions Notes ...
Страница 78: ... 2018 ACP Inc Cedar Rapids IA 52404 Page 78 of 80 Part No 16400033 Original Instructions Notes ...
Страница 79: ... 2018 ACP Inc Cedar Rapids IA 52404 Page 79 of 80 Part No 16400033 Original Instructions Notes ...
Страница 80: ... 2018 ACP Inc Cedar Rapids IA 52404 Page 80 of 80 Part No 16400033 Original Instructions www acpsolutions com ...