41
KOOLMASTER PP20-VS2 rev.00
KOOLMASTER PP20-VS2
Feeder monitoring —
Select
“Yes”
if you
want the controller to monitor the run time
of feeding inputs. If this alarm condition is
enabled, set the maximum run time of each
feeder (in minutes). Refer to section 4.8 to
assign the relay that must open in case of a
run time alarm. *
Accessible if feeders are enabled
(section 4.5).
T° Probe Difference —
Select
“Yes”
if you
want the controller to sound an alarm if the
Current Conditions
Set Point
Min. Vent.
Start/Stop
Inlets
History
Age/Mortal
Clean Mode
Monitoring
Program
Selection
Setup
Time/Date
Use to navigate
Clear Warning 1?
No
Room Temperature
72.3 °F
Current Stage
2
Current Probe
Set 1
Set Point
70.0 °F
Inside Humidity
Low %
Outside Humidity
Low %
Static Pressure
.000 “WC
Outside T°
High °F
Heating Stages
xx
Clock Output
xx
Inlet 1 Position
0 %
V1 Current Speed
100 %
V2 Current Speed
100 %
Running Prog:
Program 1
Yesterday Lo Room T
71.2 °F
Yesterday Hi Room T
74.5 °F
Yesterday Water 1
0 Gal
last 24H Water 1
0 Gal
Previous 24h Water 1
0 Gal
Yesterday Water 2
0 Gal
L.24H Water/Hd*
.0000 Gal
[*Water consumption per head, last 24h]
P.24H Water/Hd**
.0000 Gal
[*Water consumption per head, previous 24h]
Temperature Probe 1
72.3 °F
Temperature Probe 2
72.4 °F
Yesterday RH Min
0 %
Yesterday RH Max
0 %
Yesterday feeder 1
0 min
temperature difference between two probe
readings gets too high.
T° Difference —
If the temperature probe
difference alarm condition is enabled above,
specify the temperature difference above
which the controller must sound an alarm.
Activate the alarm relay —
Select
“Yes”
if you
want the controller to activate the alarm relay
when the following alarm conditions occur:
MONITORING FUNC-
13.
TIONS
13.1. Current Conditions
The current condition menu gives a
quick overview of the actual condi-
tions in the barn.
Select:
1.
Main menu
The current conditions (inputs and output)
2.
are shown on screen. Use the arrow keys to
scroll the display.
- Water spill
- Lo / Hi Water usage
- Lo / Hi Temperature
- Lo / Hi Static pressure
- Defective sensors: temperature, hu-
midity, static pressure)
- Comm. error with the RP-16
- Defective potentiometer
- Defective whisker switch
- Zero Crossing (variable module failure)
[Alarm conditions that activate the alarm relay are
common to all programs].
13.2. History Menus
History menus give a daily record of probe
readings and of the animal count. These
pieces of information are logged into history
menus at midnight. Refer to section 13.2 to
consult run time histories (for heaters, water
consumption and feeders).
Select:
1.
Current Conditions (Main Menu)
History
Select the desired type of history:
Room temperature —
This menu contains the
daily minimum and maximum readings of the
room temperature of the past 60 days.
Probe temperature —
This menu contains the
daily minimum and maximum temperature
readings of each temperature probe for the
past 10 days.
Outside temperature —
This menu contains
the daily minimum and maximum readings of
outside temperature probes for the past 75
days. *
Accessible if an outside temperature sensor
is enabled (section 4.7.1).
Inside relative humidity (RH) —
This menu
contains the daily minimum and maximum
inside humidity readings of the past 75 days.
* Accessible if the inside humidity sensors is enabled
(sec. 4.7.1).
Outside relative humidity (RH) —
This menu
contains the daily minimum and maximum
outside humidity readings of the past
75 days. *
Accessible if the outside humidity sensors
is enabled (sec. 4.7.1).
Static Pressure —
This menu contains the
daily minimum and maximum static pressure
readings of the past 75 days. *
Accessible if the
static pressure sensors is enabled (sec. 4.7.1).
Mortality / Culled / Marketed —
These menus
contains the daily count of mortalities, culled,
and of marketed animals of the past 75 days.
*Accessible if age-based functions are enabled
(section 4.5). In addition, mortality information
can be sorted in 8 different history menus (refer
to the section 4.5 to enable the desired number of
mortality menus.
Water Consumption —
This menu contains
the daily water consumption measured by
each water meter for the past 75 days. *
Ac-
cessible if at least one water meter is enabled in
section 4.7.
Heater Run Time —
This menu contains the
daily run time of each heating output for the
past 75 days.
Feeder Run Time —
This menu contains the
daily run time of each feeding output for the
past 75 days. *
Accessible if feeders are enabled
in section 4.5.
Resetting the run time of a feeder —
To
reset the run time of a feeder, select the
“Reset” feeder tab then follow the prompts
on screen.
Содержание Koolmaster PP20-VS2
Страница 47: ......
Страница 48: ...REV 00 M 890 00527 rev 00 ...