4.5. Installation Setup
The following section shows how to cus-
tomize the controller for your particular
application. It shows how to enable and set
the outputs of your controller. Normally, this
setup needs to be done only once.
Unshared Parameters
4.5.1.
The following parameters must be set sepa-
rately for each controller program in use.
Select:
1.
Current Conditions (Main Menu)
Setup *
User
Installation
* A password may be required to access this menu.
Hint: use the right and left arrow keys to
move up and down through the display
by pages.
Set the following parameters:
2.
Running Prog: —
This is the program cur-
rently being used by the controller (it is not
necessarily the program being displayed on
screen (see
“Show Settings”
below)). *
This piece
of information is shown for consultation purposes
only. Refer to section 4.3.1 if you want to change
the program in use.
Show Settings —
The settings displayed on
screen are related to this program (they are
not necessarily related to the program in use).
*
This piece of information is shown for consultation
purposes only. Refer to section 4.3.1 if you want to
change the program to be displayed.
Number of feeders —
The controller has 2 in-
puts that are used to monitor the run time of
feeder motors. Enable the proper number of
feeder inputs (0 to 2 feeders).
Number of heating stages —
Enable the
proper number of heating stages (0 to 3
heating stages).
Number of fan stages —
Enable the proper
number of fan stages (1 to 12 fan stages).*
The
number of fan stages is limited by the stage number
that signals the beginning of tunnel ventilation. Refer
to section 6.4 to select the first tunnel stage.
Number of clock outputs —
Enable the
proper number of clock outputs (0 to 2 clock
outputs).
Number of clock cycles —
If clock outputs
are enabled, select how many timers (cycles)
each output uses (1 to 12 cycles).
Number of 0-10V outputs —
Enable the proper
number of 0-10V outputs (0 to 2 outputs).
Number of natural ventilation curtains —
Enable the proper number of natural ventila-
tion curtains (0 to 2 curtains).
Curtain Compensation —
Select
“Yes”
to en-
able a compensation on the opening of natural
ventilation curtains as a function of the outside
temperature. *
Accessible if natural ventilation cur-
tains are enabled above and if an outside temperature
sensor is enabled in sec. 4.7.1.
Number of Tunnel Doors —
Enable the proper
number of tunnel doors (0 to 2 tunnel doors).
Use a Second Set of Probes —
Select
“Yes”
to use a second set of probes to measure the
room temperature when the controller is in tun-
nel ventilation or select
“No”
to keep using the
same set of probes for all ventilation modes.
Number of Inlets —
The controller can control
two air inlets. Enable the proper number of
inlets.
Variable fans (Ramping) —
Select
“V1”
to
enable variable output 1; select
“V1-V2”
to
enable variable outputs 1 & 2; select
“None”
to disable variable outputs (if variable fans
are not used, the controller will automatically
ramp up the fan speed of stage 1 to make a
smooth transition between minimum ventila-
tion cycles and fan stage 1).
Misting—
The controller can control one misting
output. Select
“Yes”
to enable this output.
Kool-Cels® —
The controller can control one
Kool-Cel® output. Select
“Yes”
to enable this
output.
Stir fans —
The controller can control one
stir fan output. Select
“Yes”
to enable this
output.
Soaking —
The controller can control one soak-
ing output. Select
“Yes”
to enable this output.
Lights —
The controller can control one light
output. Select
“Yes”
to enable this output.
# Cycles Light —
Enable the desired number
of light cycles (from 1 to 5). *
This parameter is
accessible if the light output is enabled above.
Close inlets in natural —
Select
“Yes”
for inlets
to close when the controller enters in natural
ventilation. *
Accessible if natural ventilation cur-
tains and vent inlets are enabled.
Installation
Use to navigate
Running Prog:
Program 1
Show Settings:
Program 1
Unshared Parameters
# Feeders
2
# Heater stages
3
# Fan stages
8
# Clocks
2
# Cycles Clock 1
12
# Cycles Clock 2
12
# 0-10V Outputs
2
# Natural Curtain
2
Use Curtain 1 Compens.
Yes
Use Curtain 2 Compens.
Yes
# Tunnels
2
Use Second Set Probe?
Yes
# Inlets
1
Variable?
V1,V2
Use Misting?
Yes
Use Kool-Cel?
Yes
Use Stir Fan?
Yes
Use Soaking?
Yes
Use Light?
Yes
# Cycles Light
4
Close Inlet in Natural
Yes