42
KOOLMASTER PP20-VS2 rev.00
KOOLMASTER PP20-VS2
Current count —
The current count is au-
tomatically adjusted as mortalities or culled
animals are posted.
Starting a new group —
Before starting
a new group, enter the animal age and the
initial count.
ALL histories of the controller & all water
consumption data are reset when a new
group starts.
New mortalities —
Mortality information can
be stored in different history menus. Prior to
posting a new mortality value, select the proper
mortality history menu (type 1-8). After having
selected the history type and posted the new
mortality value, the mortality value shown on
screen automatically goes back to “0”. The
posted value is then added to the total mortal-
ity count and removed from the current animal
count. *
Refer to section 4.5 to enable the desired
number of mortality history menus.
New culled —
Post the number culled ani-
mals as it occurs. Once it is validated, the
parameter value automatically goes back to
“0”. The posted value is added to the total
culled count and removed from the current
animal count.
New marketed —
When new pigs are sold,
post the number marketed animals. Once it is
validated, the parameter value automatically
returns to “0”. The value is added to the total
marketed animal count.
13.3. Animal Age & Count
Animal age:
Some parameters of the con-
troller can automatically change over time
as the animals grow up (curves, programs
& tunnel door). Using age-based parameters
is optional, refer to section 4.5 to enable or
disable the animal age function.
Animal count
(Current count / mortality / culled / marketed):
At the beginning of a group, the user must
specify the initial number of animals. After-
wards, the user can specify the number of
mortalities, culled, and marketed animals as
it occurs.
ALL histories of the controller & all water
consumption data are reset when a new
group starts.
Select:
1.
Current Conditions (Main Menu)
Age/Mortality*
* Accessible if age-based functions are enabled in
the Installation Setup (section 4.5)
Age & Mortality
Animal Age
-4 day
Initial Count
1200
Current Count
1200
Start New Group?
No
Select Mortal:
Type 1
New Mortality
0
Today’s Mortality
0
Total Mortality
0
New Culled
0
Today’s Culled
0
Total Culled
0
New Marketed
0
Today’s Marketed
0
Total Marketed
0
Set the following parameters:
2.
Animal age —
The animal age can be adjusted
from -5 days to 450 days. Negative day values
are used to prepare the house before letting
the animals in.
Initial count —
Enter the initial number of
animals in the room before enabling the new
group.
13.4. Automatic Reminder
The controller can display warning messages
at regular intervals. The automatic reminder
allows you to associate a warning message to
a servicing activity for instance then decide
the frequency at which this servicing activity
must be performed. In all, the controller can
display 3 different warning messages.
When a warning message is active, the word
“Warning” is displayed on screen, along with
the message number.
Select:
1.
Current Conditions (Main Menu)
Setup*
User
Warning
* A password may be required to access this menu.
Warning Message Settings
Show Warning1 every
10 days
Show Warning2 every 100 days
Show Warning3 every Off days
Clear Warning 1?
Yes
Set the following parameters:
2.
Show warning 1-3 every —
Select the fre-
quency at which each warning message is
displayed (1 to 450 days); select
“Off”
to
disable a warning message.
It is suggested to write down the
meaning and frequency of warning
messages 1-3:
#
MEANING
FREQUENCY
Warning 1
every ____days
Warning 2
every ____days
Warning 3
every ____days