36
KOOLMASTER PP20-VS2 rev.00
KOOLMASTER PP20-VS2
8. LIGHTS
The controller can control one light output.
The lights turn on when the
“On Time”
of a
light cycle is reached and turn off at the
“Off
Time”.
In all, you can program up to 5 daily
light cycles. Refer to section 4.5 to enable
the desired number of cycles.
Select:
1.
Current Conditions (Main Menu)
Start/Stop*
Lights**
* A password may be required to access this menu.
** Accessible if the light output is enabled in the
Installation Setup (section 4.5).
Light Settings
Use to navigate
1.
On Time
6:00A h:m
Off Time
6:00A h:m
2.
On Time
6:00A h:m
Off Time
6:00A h:m
3.
On Time
6:00A h:m
Off Time
6:00A h:m
4.
On Time
6:00A h:m
Off Time
6:00A h:m
5.
On Time
6:00A h:m
Off Time
6:00A h:m
Set the following parameters:
2.
On & Off Times —
Set the On and Off times
of each lighting cycle to the desired value.
9. CLOCK OUTPUTS
The controller has 2 outputs to control various
devices using the real-time clock. These clock
output can use up to 12 timer cycles.
A clock output starts when the
“On Time”
of a
timer is reached; it either stops after a certain
run time or at a certain time of day. The fol-
lowing diagrams show both possibilities:
Time
Cycle
Output
Status
On
Start Time
(e.g. 8h30AM)
Time Clock:
Start/Stop Mode
Stop Time
(e.g. 9h00AM)
Off
Time
Output
Status
Cycle
Start Time
(e.g. 8h30AM)
Time Clock:
Start/Run Mode
Run Time
(e.g. 30m:15s)
On
Off
Select:
1.
Current Conditions (Main Menu)
Start/Stop*
Clocks**
Clock #x
* A password may be required to access this menu.
** Accessible if at least 1 clock output is enabled in
the Installation Setup (section 4.5).
Clock #x Settings
Use to navigate
Clock Mode
Start/Stop
1.
On Time
6:00A h:m
Off Time
6:00A h:m
2.
On Time
6:00A h:m
Off Time
6:00A h:m
or
Clock Mode
Start/Run
1.
On Time
6:00A h:m
Run Time Hour
0
Minutes
0
Seconds
0
Set the following parameters:
2.
Clock mode —
The clock mode allows stop-
ping a clock output at a certain time of the
day or after a certain run time. Select “
Start/
Stop”
to specify the time at which each cycle
starts and stops or select
“Start/Run”
to
specify the running time of each cycle. Note
that the
“Start/Run”
option allows stopping
cycles with more precision since this mode
allows adjusting the seconds.
On Time / Off Time or Run Time —
Set the
time at which each cycle starts then set the
moment at which each cycle ends.
Содержание Koolmaster PP20-VS2