ACL Staticide ACL-750-USB Combo Tester Instructions
2/8/2021
74
I tried the generating of the Exception Report, both manually and through email. But, still it does not have the most recent
update. Am I doing something wrong?
By “most recent update” do you mean that it generates a report but not with he most recent test data?
If this is the case, run the Reports, View Entire Log. Make sure the most recent test date is there. If not, and if you are running from a
server (i.e. you are not running from the local test station), you either need to run the Logsort.exe program (manually or
automatically), or have all test stations running from the same log.txt file by settings their working directories to the same folder. We
recommend the logsrt.exe method. Please read the manual on how to set up the netlist.txt file with the proper test station paths.
Also make sure that the dates in the Log.txt data are in chronological order. A sudden jump forward to the future can cause the
report generator to stop searching.
Does the Exception Report get updated automatically after each test?
No. The exception report does not get updated after each test, it needs to be run either:
1.
Manually from the Reports, Exception menu or
2.
Automatically from the AutoGenerate mail window.
I get an error saying: Runtime error '339' - Component 'msmapi32.ocx' or one of its dependencies not currently registered:
a file is missing or invalid?
This file is included on our installation disk and should have been automatically installed by our installation CD. So here are your
options:
a. Try uninstalling and reinstalling the software using the latest version.
b. If that does not work, try installing the file manually:
- Copy the file from the CD
D:\System32\Redist\MS\System\msmapi32.ocx
to your system directory
C:\WIndows\System32
- Register it by clicking Start, Run, and type:
regsvr32 c:\Windows\System32\msmapi32.ocx
I get an error saying: Runtime error '339' - Component “Threed32.ocx ' or one of its dependencies not currently registered:
a file is missing or invalid?
This file is included on our installation disk and should have been automatically installed by our installation CD. So here are your
options:
a. Try uninstalling and reinstalling the software using the latest version.
b. If that does not work, try installing the file manually:
- Copy the file from the CD at
D:\System32\Redist\MS\System\Threed32.ocx
to your system directory
C:\WIndows\System32
- Register it by clicking Start, Run, and type:
regsvr32 c:\Windows\System32\Threed32.ocx
When the operator scans his/her badge, a DOS window pops up, and I have to close it myself manually. What can I do?
The DOS window is caused by the Synch.bat program (Refer to the manual). If you are running multiple test stations you need to
synchronize the ties to the server If you have another way of doing this then just rename the synch.bat file to something else like
Synch.bak and disregard the rest of the instructions listed below:
1.
Using Windows Explorer, right click on the Synch.bat file, select Edit (this will open the Synch.bat file in Notepad for editing) and
make sure the server computer name is correctly saved and exit.
2.
Using Windows Explorer, double left click on the Synch.bat file to run it. Make sure it runs correctly with no error message. Close the
DOS window.
3.
Using Windows Explorer, right click on the Synch.bat file, select properties and click the box that says “Close on Exit”.
Can I use other data base programs for generating my Names.txt file?
Our database input file names.txt is extremely simple - it is just a text file with the fields separated by commas, with a record (line of
text) for each employee. In almost every data base program ever designed (including Excel and MS Access), it can be generated by
exporting the data as a .csv file. If you can export your employee data base with just three fields per employee - last name, first
name, and badge#, our program will fill in the remaining fields with default values.
www.
.com