ACL Staticide ACL-750-USB Combo Tester Instructions
2/8/2021
27
Change All Limits.
This is under the ‘Setup Menu’ “Change All Limits’. This screen can be used to reset the parameters for the wrist and foot strap
alarm resistances of all employees. The wrist strap and heel grounder defaults may also be selected. Resistance values from 0.10
megohms to 99.99 megohms for the minimum and maximum alarm conditions may be entered. *A special 1000 megohm model
PROM is also available. However, it is recommended that you enter the alarm conditions at which the combo tester internal
dipswitches are set. These may be determined later by running a test and reading the set point conditions in the ‘Received’ window.
The dip switch setting on the combo tester overrides the “Wrist Used” and “Foot Used” criteria in the user ‘Setup’ menu.
By using “DipSw or ”-1 in all fields, the parameter settings will automatically match the dipswitch settings inside the meter. For
example, the wrist low would be .75 because dipswitch 2 is turned on. If the user puts dipswitch 2 to the off position (.5M), -1 would
then be .5 Megs. (See limit switch settings chart).
Change Administrator Password
A password protection can be activated in order to access the setup parameters and the data. . Select ‘Change Password’ under
‘Setup’ and type in the new password.
If using a password, it will only be asked for once. If a password was previously entered and is no longer required, select ‘Change
Password’ and leave the field blank when selecting a new one.
Unknown ID Configuration’
The program will also allow automatic addition of new badges if an unknown badge number is read during testing. This may be
enabled in the ‘Unknown ID Configuration’ menu under the ‘Setup’.