LIMITED WARRANTY 

Accutrol  LLC,  having  its  principal  place  of  business  at  21  Commerce  Drive,  Danbury,  CT  USA 
("Manufacturer") warrants its AccuStation

®

, Model VTS product (the "Products") as follows: 

1.  Limited Warranty.  
Manufacturer warrants that the Products sold hereunder will be free from defects in material 
and workmanship for a period of sixty (60) months from the date of purchase.  If the Products 
do  not  conform  to  this  Limited  Warranty  during  the  warranty  period  (as  herein  above 
specified), Buyer shall notify Manufacturer in writing of the claimed defects and demonstrate to 
Manufacturer

’s

  satisfaction  that  said  defects  are  covered  by  this  Limited  Warranty.    If  the 

defects are properly reported to Manufacturer within the warranty period, and the defects are 
of  such  type  and  nature  as  to  be  covered  by  this  warranty,  Manufacturer  shall,  at  its  own 
expense,  furnish,  replacement  Products  or,  at  Manufacturer's  option,  replacement  parts  or 
services  for the defective  Products.    Shipping  and  installation  of the replacement Products or 
replacement parts shall be at Buyer's expense. 

2.  Other Limits. 
THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT 
NOT  LIMITED  TO  THE  IMPLIED  WARRANTIES  OF  MERCHANTABILITY  AND  FITNESS  FOR  A 
PARTICULAR PURPOSE.  Manufacturer does not warrant against damages or defects arising out 
of  improper  or  abnormal  use  or  handling  of  the  Products;  against  defects  or  damages  arising 
from improper installation (where installation is by persons other than Manufacturer), against 
defects  in  products  or  components  not  manufactured  by  Manufacturer,  or  against  damages 
resulting from such non-Manufacturer made products or components.  Manufacturer passes on 
to  Buyer  the  warranty  it  received  (if  any)  from  the  maker  thereof  of  such  non-Manufacturer 
made  products  or  components.    This  warranty  also  does  not  apply  to  Products  upon  which 
repairs  have  been  affected  or  attempted by persons  other than  Manufacturer  or  pursuant to 
written  authorization  by  Manufacturer.

   

This  warranty  also  does  not  apply  to  any  product 

provided by the Buyer and mounted by the Manufacturer to Products.

 

3.  Exclusive Obligation. 
THIS WARRANTY IS EXCLUSIVE.   The sole and exclusive obligation of Manufacturer shall be to 
repair  or  replace  the  defective  Products  in  the  manner  and  for  the  period  provided  above.  
Manufacturer  shall  not  have  any  other  obligation  with  respect  to  the  Products  or  any  part 
thereof,  whether  based  on  contract,  tort,  and  strict  liability  or  otherwise.    Under  no 
circumstances,  whether  based  on  this  Limited  Warranty  or  otherwise,  shall  Manufacturer  be 
liable for incidental, special, or consequential damages. 

4.  Other Statements. 
Manufacturer's employees or representatives' ORAL OR OTHER WRITTEN STATEMENTS DO NOT 
CONSTITUTE WARRANTIES, shall not be relied upon by Buyer, and are not a part of the contract 
for sale or this limited warranty. 

5.  Entire Obligation. 
This  Limited  Warranty  states  the  entire  obligation  of  Manufacturer  with  respect  to  the 
Products.  If any part of this Limited Warranty is determined to be void or illegal, the remainder 
shall remain in full force and effect. 

Содержание VTS

Страница 1: ...odel VTS Contents of this Manual are Subject to Change Without Notification Airflow Measurement Station Manufactured by Accutrol Representative VTS MANUAL REV A AccuStation 21 Commerce Drive Danbury C...

Страница 2: ...st defects or damages arising from improper installation where installation is by persons other than Manufacturer against defects in products or components not manufactured by Manufacturer or against...

Страница 3: ...TABLE OF CONTENTS LIMITED WARRANTY ii TABLE OF CONTENTS iii SECTION 1 INTRODUCTION 4 SECTION 2 SPECIFICATIONS 5 SECTION 3 PHYSICAL DIMENSIONS WEIGHTS 9 SECTION 4 INSTALLATION 10 SECTION 5 WIRING 13 S...

Страница 4: ...l pulses generated by each vortex shedding sensor are used to calculate the total airflow volume flowing through the AccuStation The transmitter provides a software selectable analog output signal tha...

Страница 5: ...s USB Configuration Port and Factory Cable Terminal Plugs 3 position vertical pluggable screw on top wire size 12 30 AWG EMC Safety EN 61326 1 2013 2014 35 EU LVD 2014 30 EU EMC EN 61010 1 2010 FCC Pa...

Страница 6: ...0 15 0 20 0 25 0 30 0 35 0 40 0 45 25 50 75 100 125 150 175 200 225 250 275 300 325 Station DP wc Max Airflow CFM 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 100 150 200 250 300 350 400 450 500...

Страница 7: ...00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 300 600 900 1200 1500 1800 2100 2400 2700 Station DP wc Max Airflow CFM 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 400 800 1200 1600 2000 2400 2...

Страница 8: ...05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 800 1600 2400 3200 4000 4800 5600 6400 Station DP wc Max Airflow CFM 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 1000 2000 3000 4000 5000 6000 7000 80...

Страница 9: ...imensions are to the outside and have a tolerance of 062 1 6mm Model Size Dimensions Weight D L H Stainless Steel Aluminum in mm in mm in mm Lbs kg Lbs kg 06 5 88 149 22 559 10 254 11 5 0 7 3 2 08 7 8...

Страница 10: ...be sure to select a location that will provide a minimum clearance of 14 356mm unobstructed access to the transmitter and station access cover 3 Provide an opening in the duct section sized appropria...

Страница 11: ...ARGE INLET 4 Secure station to duct using tek screws 6 Secure both ends of station to the duct using draw band clamps 2 Slip the station inlet into the fan side of the duct far enough to allow the sta...

Страница 12: ...sed Also verify both ends of the duct where the station is to be attached are true and square before attempting to install station If the duct ends are not square and true do not attempt to install st...

Страница 13: ...gure below is shown with the optional BACnet module installed and the remote monitor connected 24 vAC 24 vDC or Analog Input BMS Controller Signal Receiving Device Common Power Source BACnet MSTP Bus...

Страница 14: ...om the factory by performing the following steps Note This process will require an automatic email to be generated from your computer therefore you will need to have internet access to generate the ke...

Страница 15: ...transmitter through the computer connected to the USB Configuration Port This is a temporary position only Note The Power Source Switch must be returned to the Operational Position after completing th...

Страница 16: ...lect Locate Accutrol Devices then select the com port associated with the VTS that your computer is connected to 6 5 1 Insight Dashboard The Insight Dashboard is the primary screen for accessing the t...

Страница 17: ...log Output or it can be configured with a full scale range that is independent of the Analog Output To change the full scale range click on the gauge face 6 5 5 Analog Output Configuration The VTS s A...

Страница 18: ...Source Manual Output 6 5 6 Sensor Frequency Signals The AccuStation measures airflow using vortex shedders that are incorporated in the compression zone of each chamber inside the station Each vortex...

Страница 19: ...rom the factory The current configuration settings will be replaced Save To Transmitter Flash Memory This will save the contents of the transmitter RAM memory to the transmitter nonvolatile FLASH memo...

Страница 20: ...uStation or advisable and is only provided as a tool for the Airflow Balancer to correlate the VTS airflow measurement to a field airflow measurement The graph below shows the effect the Equal Cal Adj...

Страница 21: ...output full scale range BACnet Configuration Opens a window required for configuring the BACnet VIEW System Info Provides the status of Transmitter connections Transmitter Identification Provides the...

Страница 22: ...utrol VTS Transmitter product family supports a collection of BACnet visible objects which are defined in the following table Point Object Description Present Value Type Units DE Device Instance Write...

Страница 23: ...es which are not retained when the power to the transmitter is lost Values stored in Flash memory are copied to RAM memory during the power up sequence of the transmitter Writing a value of one 1 to t...

Страница 24: ...lt enough to allow the access door to slide forward CAUTION If the bolt is removed from the captive nut the access cover can spring open possibly causing injury 8 1 2 Using two hands squeeze the acces...

Страница 25: ...ver is secured to the station using 4 2 blunt head Phillips head screws To inspect the sensors remove the access cover by removing the screws using a 2 Phillips head screw driver Put the screws aside...

Отзывы: