86
Conductivity Setup:
Select Reference Temperature
XL20, 30, 50 and 60 meters
Set Default Temperature
Conductivity is a temperature dependent measurement. This option allows you to select a default
temperature that the meter will use along with the temperature coefficient to calculate a
temperature corrected conductivity measurement.
If an ATC probe is used any value entered as a default temperature will be overridden in favor of
the actual measured temperature of the solution provided to the meter by the ATC probe.
The default temperature can be set from -10°C to 110°C.
To set Default Temperature
1. Select temperature units by touching the appropriate unit button:
C
(Celsius),
F
(Fahrenheit) or
K
(Kelvin).
2. Touch the
Default Temperature box
and use the numeric keypad to enter the desired
default temperature (-10°C to 110°C).
3. Press
Enter
in the keypad to return to conductivity Setup screen.
Set Reference Temperature
This setup option allows you to select the reference temperature to be used in the determination
of the conductivity of your sample. The reference temperature is the temperature to which the
conductivity readings would be normalized.
The reference temperature can be set from 15°C to 30°C.
To set Reference Temperature
1. Select temperature units by touching the appropriate unit button:
C
(Celsius),
F
(Fahrenheit) or
K
(Kelvin).
2. Touch the
Reference Temperature box
and use the numeric keypad to enter the desired
default temperature (15°C to 30°C).
3. Press
Enter
in the keypad to return to conductivity Setup screen.
accumet
®
conductivity cells for the XL60 have a built-in Temperature sensor.
Note:
The units of all temperature parameters must match. The meter will automatically
modify the temperature units of Default Temperature and Reference Temperature to match
the last choice made on any of these parameters.
Содержание XL 20
Страница 1: ......
Страница 138: ...127 Ion Operation Known Addition Method XL25 50 and 60 meters...
Страница 140: ...129 Ion Operation Known Subtraction Method XL25 50 and 60 meters...
Страница 142: ...131 Ion Operation Analate Addition Method XL25 50 and 60 meters...
Страница 144: ...133 Ion Operation Analate Subtraction Method XL25 50 and 60 meters...