44
41
P5:
RELAY LOGIC SELECTION
Through this parameter it is possible to invert the control logic
of the relays, or to transform the output from Normally Open
(N.O.) to Normally Closed (N.C.) and vice versa.
It will be possible to modify only the logic of the outputs that the
selected scheme foresees as active.
By changing the scheme using parameter 1, all the output logics
will be reset to the N.O. (default).
If the parameter is not active in the selected scheme, the display
will show 'NONE'.
SELECTED PARAMETER P5
PRESS THE BUTTON
‘
8
’
THROUGH THE ARROWS
‘
’ o
r
‘
’
YOU
CAN SCROLL THE ACTIVE OUTPUTS
PRESS KEY
‘
8
’
TO CONFIRM THE SETTING MADE
OR PRESS THE 'esc' KEY TO CANCEL THE CHANGE
The outputs whose logic can be changed are a maximum of 3 and
are listed below.
Logic output
OUT 2
Dat
a
Adjustment range
Default
OUT 2
0 .. 1
1
Logic output
OUT 3
Dat
a
Adjustment range
Default
OUT 3
0 .. 1
1
Logic output
OUT 4
Dat
a
Adjustment range
Default
OUT 4
0 .. 1
1
Note: '0' logic means NC relay, while '1' logic means NO relay.
P6:
ACCOUNTING HOURS OF INTEGRATION
With this parameter it is possible to view and reset the hours of
actual activation of the integration source.
SELECTED PARAMETER P6
PRESS THE BUTTON
‘
8
’
THE DISPLAY SHOWS 'H' AND THE ACTUAL HOURS
OF ACTIVATION OF THE INTEGRATION SOURCE
PRE
SS
‘
8
’ DISPLAY
SHOWS
‘ H’
FLASHING
PRE
SS
‘
8
’
THE COUNTER IS RESET BY PRESSING INSTEAD 'esc'
YOU RETURN TO DISPLAY OF THE CURRENT HOURS
The count of the integration activation hours is between 0000 ..
9999.
When the maximum value is reached, the count will stop.
P7:
TEST CONNECTED LOADS
Through this parameter it is possible to carry out the functional test of
the loads connected to the control unit.
The control unit activates the connected loads, according to the
configured scheme, activating all the available outputs in sequence
for 10 seconds each, including the alarm relay and the relative
buzzer. The test sequence, in multiples of 5, can be set using the only
parameter present 'TMR'.
The activation of the test will be signaled on the display with the
lighting up of the 'TIMER' icon.
ATTENTION
The activation of the alarm relay will be indicated on the display
by the flashing 'TIMER' icon and by the activation of the buzzer
in order to also test the emission of acoustic signals.
SELECTED THE PARAMETER
P7
PRE
SS KEY
‘
8
’
DISPLAY
SHOWS
‘ TMR ’
FLASHING
USING THE KEYS
‘
’ o
r
‘
’
THE NUMBER OF
CYCLES CAN BE VARIED
5, 10, 15, 20, 25
PRE
SS
‘
8
’
THE SET DATA IS CONFIRMED AND THE
LOAD TEST STARTS. HOWEVER, PRESSING 'esc'
CANCELS THE CHANGE AND RETURNS TO DISPLAYING
THE NUMBER OF PRESET CYCLES
Impostazione sequenza test
Dato
Campo regolazione
Default
TMR
05 .. 25
05
P8:
ACCOUNTING OF PRODUCED ENERGY
Through this parameter it is possible to manage the data
relating to the measurement of the amount of heat produced by
the system.
The amount of energy produced will be stored in the memory of
the control unit approximately every 2 hours.
If the stored flow value is equal to zero, the display will show
'FLOW OFF' and the energy calculation will be inactive.
If you want to reset the energy meter produced, select the
'RESET' parameter and press the 'ENTER' key.
If the parameter is not active in the selected scheme, the display
will show 'NONE'.
SELE
CT PARAMETER
P8
PRE
SSING KEY
‘
8
’
LE FRECCE
‘
’ o
r
‘
’
È POSSIBILE SCORRERE
CICLICAMENTE TRA I PARAMETRI DI
CONTABILIZZAZIONE DI ENERGIA PRODOTTA:
-
System flow rate liters / minute
‘FLOW’
- Resetting of energy produced counters
‘RST’
PRE
SS KEY
‘
8
’
TO ENTER THE SELECTED
PARAMETER;
THE PARAMETER STARTS TO FLASH
SET THE DESIRED NUMERICAL VALUE USING
THE ARROWS
‘
’ o
r
‘
’
(
only for the parameter
FLOW)