14
HR 7.8
8,12
1,96
4,14
7,75
2,52
3,07
6,73
2,00
3,37
6,44
2,54
2,53
5,52
2,00
2,76
5,20
2,53
2,05
3,71
150,30
1
1
Reverse cycle with immersion condenser
R410A
+30 / +58
2,0
3
5
15
5
5/8”
1/4”
68,4
54,7
230V/1/50Hz
2,53
11,57
55
4.7 TECHNICAL DATA TABLE BOOSTER HUB RADIATOR PLUS / PLUS SOLAR
HR 9.0 INVERTER
3,54 / 8,01 / 8,81*
1,89
4,24
2,85 / 7,92 / 8,71*
2,39
3,31
2,54 / 7,04 / 7,74*
2,15
3,52
2,46 / 6,82 / 7,50*
2,74
2,68
2,31 / 6,41 / 7,05*
2,31
3,04
2,25 / 6,25 / 6,88*
2,78
3,39
3,94
159,62
A++ / A+++
Twin Rotary DC INV.
2,2
5/8”
3/8”
64,0
32,8
-20 / +46
4,70
20,40
62
HR 3.0
3,11
0,74
4,20
2,97
0,94
3,16
2,58
0,74
3,48
2,47
0,94
2,67
2,11
0,75
2,81
1,99
0,94
2,11
3,78
153,10
1,1
3/8”
1/4”
65,1
51,2
0,94
4,30
33
U.M.
kW
kW
W/W
kW
kW
W/W
kW
kW
W/W
kW
kW
W/W
kW
kW
W/W
kW
kW
W/W
W/W
%
n.
n.
°C
kg
m
m
m
m
dB(A)
dB(A)
°C
kW
A
Kg
DESCRIPTION
Thermal power (1)
Absorbed power (1)
C.O.P. (1)
Thermal power (2)
Absorbed power (2)
C.O.P. (2)
Thermal power (3)
Absorbed power (3)
C.O.P. (3)
Thermal power (4)
Absorbed power (4)
C.O.P. (4)
Thermal power (5)
Absorbed power (5)
C.O.P. (5)
Thermal power (6)
Absorbed power (6)
C.O.P. (6)
SCOP (7)
Seasonal heating efficiency (ηs)
Energy efficiency class (8)
Type of compressor
Compressors
Refrigerant circuits
Defrost method
Type of refrigerant
Temperature technical water min/max
Amount of refrigerant (pre-inserted)
Min distance between outdoor and indoor unit
Max dist. betw. outdoor/indoor unit without recharging
Max distance between outdoor/indoor unit with recharge
Max diff. in height between outdoor/indoor unit
Refrigerant gas line connection R410A
Coolant line connection R410A
Sound power (9)
Sound pressure 1 m (10)
External temperature operating limits
Power supply
Max absorbed power
Max absorbed
Weight
-15 / +45
(1) Heating: outside air temperature
7 °C b.d. - 6 °C b.w.; inlet / outlet water temperature30/35 °C
(2) Heating: outside air temperature
7 °C b.d. - 6 °C b.w.; inlet / outlet water temperature 40/45 °C
(3) Heating: outside air temperature
0 °C b.d.; water temperature inlet/outlet 30/35 °C
(4) Heating: outside air temperature
0 °C b.d.; water temperature inlet/outlet 40/45 °C
(5) Heating: outside air temperature
-7 °C b.d.; water temperature inlet/outlet 30/35 °C
(6) Heating: outside air temperature
-7 °C b.d.; inlet / outlet water temperature 40/45 °C
(7) Heating: condizioni climatiche medie; temperatura acqua ingresso/uscita 30/35 °C
(8) Water 35 °C / 55°C
(9) Measurements made according to UNI EN 14511
in heating mode and boundary conditions (1)
(10) Value calculated according to ISO 3744: 2010
(*) By activating the maximum HZ function
A++ / A
Rotation ON-OFF
4.8 DHW WITHDRAWAL TABLE HUB RADIATOR PLUS / PLUS SOLAR 250
DESCRIPTION
DHW withdrawal at 40 °C - storage at 55 °C - inlet water at 10 °C
DHW withdrawal at 40 °C - storage at 55 °C - inlet water at 15 °C
HP recovery time from 38 °C to 55 °C - Outdoor temp. 7 °C *
HP recovery time+resistance from 38 °C to 58 °C - External temp. 7 °C*
Water withdrawal at 40 °C with storage at 62 °C with inlet water at 10 °C
Water withdrawal at 40 °C with storage at 62 °C with inlet water at 15 °C
HP recovery time+resistance from 38 ° C to 62 °C - External temp. 7 °C*
Recovery time from 10 °C to 55 °C - Outdoor temp. 7 °C*
U.M.
l
l
min
min
l
l
min
min
HR 7.8
212
242
36
24
254
290
44
88
HR 3.0
202
218
82
54
228
262
98
226
HR 9.0 inverter
212
242
30
20
254
290
36
84
*Data calculated with the heating system off