GENERAL WARNINGS 

 

1.

 

Keep this Instruction Manual available for 
future reference. 

2.

 

These instructions must be adhered to 
ensure the safe and effective use of this 
bed and the safety of users and carers. 

3.

 

This bed must be assembled, positioned 
and used in accordance with these 
instructions. 

4.

 

The safety features for operating the bed 
and instructions concerning the bed must 
be strictly observed.

 

5.

 

This bed must not be exposed to smoke, 
naked flame, extreme temperature, 
flammable gasses or other hazardous 
substances or situations.

 

6.

 

Accora shall not be held liable for any 
damage, injuries or accidents arising from 
unauthorised modifications, non-genuine 
spare parts, negligence or use that is at 
variance with this manual.

 

7.

 

Electrical equipment can be hazardous if 
misused or abused. Ensure the electrical 
supply cable is not damaged by crushing 
and does not create a trip hazard. 

8.

 

Only use side rails, and other accessories, 
that are compatible with this bed as 
supplied by Accora. Incompatible side 
rails can create serious hazards. 

9.

 

Keep children and pets away from this 
bed unless supervised by an adult as there 
is a risk of injury and/or choking on small 
parts. 

10.

 

Do not lower the bed while a hoist that 
extends beneath the bed is being used. 
Hoist access is obtained when the bed is 
raised to 45cm measured from the floor to 
the mattress platform base. 

11.

 

When routing cables for other electronic 
equipment used with the bed (e.g. air 
mattress pump), please ensure cables 
cannot be squeezed, crushed or 
damaged by the moving parts on the 
bed. 

12.

 

The hand control should be positioned to 
avoid strangulation risk. Inappropriate use 
of the hand control (e.g. kinking, shearing) 
could lead to dangerous electric hazards. 
The bed must not be used if there is any 
visible damage to the handset or cable. 

13.

 

Inappropriate use of the power supply 
cord (e.g. kinking, shearing) could lead to 
dangerous electric hazards. The bed must 
not be used if there is any visible damage 
to this cable. 

14.

 

Inappropriate routing of accessory cables, 
e.g. mattress air pump cable, could lead 
to dangerous electric hazards if the 
squeezed or crushed between moving 
parts. The bed must not be used if there is 
any visible damage to any cables.  

15.

 

The bed should be left in the Floor-level 
position when the patient is unattended in 
order to reduce risk of injury due to falls. 

16.

 

If using the electronic functions adversely 
affects the health of the patient, 
disconnect the power supply and only use 
the bed in the static mode. 

17.

 

Do not move the bed when it is in the 
Floor-level position. 

18.

 

This bed should not be used for 
transporting patients. 

19.

 

This bed is typically not suitable for 
children unless a risk assessment has been 
carried out. 

20.

 

Do not modify this bed without the 
authorisation Accora. 

21.

 

Before operating this bed, ensure the 
patient is safely positioned to remove the 
risks of bed fall, entrapment and 
imbalance. 

22.

 

Always check for any entrapment risks 
under the bed before lowering to the 
Floor-level position. 

23.

 

Electrical installations must meet local 
requirements. It is recommended that the 
bed is disconnected from the mains 
during exceptional cases (i.e. a storm). 

24.

 

Patients, or users, should be risk assessed to 
ensure they are able to understand this 
manual and to operate FloorBed safely 
and without risk to themselves and those 
around. 

25.

 

Patients, or users, should only be allowed 
to operate the bed independently if they 
are able to understand the safety 
instructions in this manual and have been 
risk assessed as appropriate to do so. 

26.

 

If the combined weight of the mattress 
and accessories exceeds 35kg, the 
maximum patient weight must be 
reduced accordingly. 

Содержание FloorBed 2

Страница 1: ......

Страница 2: ...is manual is important for realising the full potential of your new FloorBed please read it before use If you need further information please contact us at Tel 01223 206100 Fax 01223 206120 E mail inf...

Страница 3: ...electric hazards The bed must not be used if there is any visible damage to the handset or cable 13 Inappropriate use of the power supply cord e g kinking shearing could lead to dangerous electric ha...

Страница 4: ...trapped 11 If a lifting pole or infusion stand is fixed to the bed increased attention must be taken during movement lifting or tipping to the space around the lifting pole and infusion stand so that...

Страница 5: ...rking load is calculated as follows as specified by EN 60601 2 52 Maximum patient weight 150kg 23 5st 330lb Mattress 20kg 3st 44lb Accessories 15kg 2 5st 33lb TOTAL Safe working load 185kg 29st 407lb...

Страница 6: ...ress platform head section c Mattress platform foot section d Footboard e Headboard WARNING Assembly MUST be carried out by a competent person All functions MUST be tested and approved by a competent...

Страница 7: ...sert locking pin and R clip as shown in two positions 6 Insert two mattress platform joining bars and secure with locking pins and R clips as shown in two positions 7 Join the two parts of the bed tog...

Страница 8: ...oned If the medical staff state that the patient s medical condition is inappropriate for the patient to be able to adjust the bed independently the bed s position must be adjusted by the carer Please...

Страница 9: ...it stops in the Safety Stop position button 6 c Use the safety double button function to lower the bed to the Floor level position buttons 6 7 pressed together d Check all cables for risk of crushing...

Страница 10: ...s shown in Section 7 a Footboard b Headboard c Mattress platform foot section d Mattress platform head section 9 Ensure all R clips and pins are refitted so that the bed on the transport bracket is sa...

Страница 11: ...ean as described in the Cleaning Information 16 Troubleshooting The FloorBed does not function correctly 1 Is the Power on indicator light on the handset lit If not a Is the power supply plugged in an...

Страница 12: ...thin the scope of the Lifting Equipment Operations Regulations LOLER and so there is no formal legal requirement for regular inspection by a LOLER competent person The following checks must be carried...

Страница 13: ...dance RF emissions CISPR 11 Group 1 The bed uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equi...

Страница 14: ...1kV line s to line s 2kV line s to earth 1kV differential mode Not applicable Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and v...

Страница 15: ...d strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range Interference may occur in the vicinity of equi...

Страница 16: ...smitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2...

Страница 17: ...1 2010 We Accora Ltd Of Charter House Barrington Road Orwell Cambridge SG8 5QP hereby declare that Model reference FloorBed 2 Serial No Refer to product label conforms to the Requirements of Directive...

Страница 18: ...20 Accora 01223 206100 info accora uk com www accora uk com IFU FB2 001 EN Rev 1 JAN 2016...

Страница 19: ......

Отзывы: