11.

 

Mattresses selection 

 

 

 

All mattresses must be fitted and used in accordance 
with the mattresses manufacturer or supplier’s 
instructions. 

 

12.

 

Siderail selection 

 

 

13.

 

Disassembly 

 

 

1.

 

Remove all accessories, e.g. mattress, side rails, bed 
levers etc. 
 

2.

 

Using the handset, raise the mattress platform 
approximately 30cm. Loosen the 4 mattress 
platform joining bar locking screws. (Do not remove 
the R-clips and locking pins at this stage) 

 

3.

 

Fix the backrest an legrest in the flat position with 
the Velcro straps provided. 

 

4.

 

Lower the mattress platform to the Floor-level 
position and disconnect the power supply. 

 

5.

 

Remove the control box cover and unplug 
headboard and footboard lift actuators, legrest 
actuator, handset and power supply. Ensure wires 
are left free so that the bed can be dismantled 
without risk of damage to the wires. 

 

6.

 

Remove the central joining bar R-clips and locking 
pins and separate the bed into two halves. 

 

7.

 

Dismantle the headboard/mattress platform head 
end and footboard/mattress platform foot end by 
removing the R-clips and locking pins.  

 

8.

 

Ensure the disassembled parts are fitted to the 
transport bracket in the following order and 
positioned as shown in Section 7: 

a.

 

Footboard 

b.

 

Headboard 

c.

 

Mattress platform foot section 

d.

 

Mattress platform head section 

 
9.

 

Ensure all R-clips and pins are refitted so that the 
bed on the transport bracket is safe to move.  
 

10.

 

Ensure all wires are secure to prevent damage. 

WARNING 

 
Incompatible mattresses can create hazards. 
Read instructions for use. 
Mattress dimensions must not exceed 2000 x 
900 x 200mm. The distance from the top of the 
uncompressed mattress to the top of the 
siderail must always be greater than 220mm 
Where a speciality mattress or mattress 
overlay is used and the distance from the top 
of the uncompressed mattress to the top of 
the siderail is less than 220mm a risk 
assessment must be performed to assure 
equivalent safety. 

WARNING 

 

Only use side rails that are compatible with 
this bed as supplied by Accora. 
Incompatible siderails can create hazards. 

WARNING 

 
Disassembly MUST be carried out by a 
competent person.  
The bed must be disconnected from the 
power supply before disassembly. 
Disassembly must take place in a clear, 
uncluttered area and children and pets 
should be kept away. 
If bed has become soiled or contaminated 
during use refer to cleaning and disinfection 
instructions. 
Extreme caution must be taken when moving 
the bed on the transport bracket to prevent 
the bed tipping over or moving unexpectedly. 

Please contact 
Accora for 
compatible 
mattresses.

 

Incompatible 
mattresses can 
create hazards. 

 

Содержание FloorBed 2

Страница 1: ......

Страница 2: ...is manual is important for realising the full potential of your new FloorBed please read it before use If you need further information please contact us at Tel 01223 206100 Fax 01223 206120 E mail inf...

Страница 3: ...electric hazards The bed must not be used if there is any visible damage to the handset or cable 13 Inappropriate use of the power supply cord e g kinking shearing could lead to dangerous electric ha...

Страница 4: ...trapped 11 If a lifting pole or infusion stand is fixed to the bed increased attention must be taken during movement lifting or tipping to the space around the lifting pole and infusion stand so that...

Страница 5: ...rking load is calculated as follows as specified by EN 60601 2 52 Maximum patient weight 150kg 23 5st 330lb Mattress 20kg 3st 44lb Accessories 15kg 2 5st 33lb TOTAL Safe working load 185kg 29st 407lb...

Страница 6: ...ress platform head section c Mattress platform foot section d Footboard e Headboard WARNING Assembly MUST be carried out by a competent person All functions MUST be tested and approved by a competent...

Страница 7: ...sert locking pin and R clip as shown in two positions 6 Insert two mattress platform joining bars and secure with locking pins and R clips as shown in two positions 7 Join the two parts of the bed tog...

Страница 8: ...oned If the medical staff state that the patient s medical condition is inappropriate for the patient to be able to adjust the bed independently the bed s position must be adjusted by the carer Please...

Страница 9: ...it stops in the Safety Stop position button 6 c Use the safety double button function to lower the bed to the Floor level position buttons 6 7 pressed together d Check all cables for risk of crushing...

Страница 10: ...s shown in Section 7 a Footboard b Headboard c Mattress platform foot section d Mattress platform head section 9 Ensure all R clips and pins are refitted so that the bed on the transport bracket is sa...

Страница 11: ...ean as described in the Cleaning Information 16 Troubleshooting The FloorBed does not function correctly 1 Is the Power on indicator light on the handset lit If not a Is the power supply plugged in an...

Страница 12: ...thin the scope of the Lifting Equipment Operations Regulations LOLER and so there is no formal legal requirement for regular inspection by a LOLER competent person The following checks must be carried...

Страница 13: ...dance RF emissions CISPR 11 Group 1 The bed uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equi...

Страница 14: ...1kV line s to line s 2kV line s to earth 1kV differential mode Not applicable Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and v...

Страница 15: ...d strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range Interference may occur in the vicinity of equi...

Страница 16: ...smitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2...

Страница 17: ...1 2010 We Accora Ltd Of Charter House Barrington Road Orwell Cambridge SG8 5QP hereby declare that Model reference FloorBed 2 Serial No Refer to product label conforms to the Requirements of Directive...

Страница 18: ...20 Accora 01223 206100 info accora uk com www accora uk com IFU FB2 001 EN Rev 1 JAN 2016...

Страница 19: ......

Отзывы: