Preface 

 
Dear customers, 
 
Many thanks for your purchase of the SECVEST 2Way wireless alarm centre. This 
device is built according to state-of-the-art technology. 
It complies with current domestic and European regulations. 
Conformity has been proven, and all related certifications are available from the 
manufacturer on request (www.abus-sc.com). 
To ensure safe operation, it is your obligation to observe these installation instructions! 
 
In the event of questions, please contact your local specialist dealer. 
 
Everything possible has been done to ensure that the contents of these instructions 
are correct. 
However, neither the author nor ABUS Security-Center GmbH & Co. KG can be held 
liable for loss or damages caused directly or indirectly by these instructions, whether 
real or alleged. 
 
We reserve the right to make changes to these instructions without prior notice. 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

© ABUS Security-Center GmbH & Co. KG, 01-2010, V 5-05-30 
 

Introduction 

 

This wireless alarm centre is used to secure your property in combination with 
detectors and transmitters. Among others, it can be used to protect your company 
premises, house, garage, summer house or weekend cottage. 
 
The alarm centre registers unauthorised break-ins by switching outputs that can be 
connected to visual, acoustic or silent alarm transmitters. 
 
The alarm centre contacts and connected components must be kept free of moisture 
(bathrooms and similar surroundings must be strictly avoided). 
Use of this product for other than the described purpose may lead to damage of the 
product. 
 
Other hazards such as short-circuits, fire, electric shock etc. are also possible. The 
PSU is designed for operation with a 230 V AC / 50 Hz mains power supply. 
No part of the product may be changed or modified in any way. 
 
Connection to the public power network is subject to country-specific regulations. 
Please be aware of applicable regulations in advance. 

 

Содержание Secvest 2WAY

Страница 1: ...1 Secvest 2Way O P E R A T I N G I N S T R U C T I O N S BOM No 12000869...

Страница 2: ...ctions without prior notice ABUS Security Center GmbH Co KG 01 2010 V 5 05 30 Introduction This wireless alarm centre is used to secure your property in combination with detectors and transmitters Amo...

Страница 3: ...ess remote control 13 12 Internal activation 14 12 1 On the system 14 12 2 Using the wireless remote control 14 13 Alarms 15 13 1 Local internal alarm 15 13 2 External alarm 15 13 3 Silent alarm 15 14...

Страница 4: ...upplied with power from the built in PSU The PSU is connected to the 230 V AC domestic mains network over a separate electrically protected line Connection work to the domestic mains network is subjec...

Страница 5: ...display 3 Integrated siren 4 Activation button 5 Deactivation button 6 Control buttons 7 Keypad alarm keys for panic fire medical and social call emergencies 8 Keypad for programming and operating th...

Страница 6: ...nu is accessed All user functions that were authorised by the installer can be accessed here Note that some functions in the user menu require a user code with administrator rights master code The fou...

Страница 7: ...ore information see chapters 11 and 12 Activating partitions and Activating internally 6 3 Remote control You can activate the complete wireless alarm system by pressing the Fully active button on the...

Страница 8: ...s are open a pulse tone is emitted during the exit delay time until all zones are closed 8 Unsuccessful activation There are two different situations here a The delay time was not started b The delay...

Страница 9: ...y important entry and exit zones should be automatically omitted e g front door cellar door back door etc Automatic omission of zones can be made in two ways a Automatic omission with confirmation b A...

Страница 10: ...mark You are prompted to enter your user code After entering the user code an acoustic message is played This is as follows Warning An alarm has been triggered A system reset is required The followin...

Страница 11: ...hows an active state via the red LED 9 3 SMS message The alarm centre sends an SMS after the delay time has expired This message shows who activated the system and when In certain circumstances transm...

Страница 12: ...on the alarm system If the chip key is authorised for deactivating one partition only this partition is now deactivated If the chip key is authorised to deactivate more than one partition all partitio...

Страница 13: ...tition have the following meanings Display Meaning U This partition remains deactivated U P This partition is activated internally U S This partition is activated S U This partition is deactivated P U...

Страница 14: ...play is shown Select the partition to be activated Change the settings for this partition The displayed codes next to the partition have the following meanings Display Meaning U This partition remains...

Страница 15: ...m system siren The info module siren The external siren the acoustic alarm is active for 3 minutes and the visual alarm is active until the system is deactivated Alarm transmission by telephone The re...

Страница 16: ...ss the control button under the exclamation mark You are prompted to enter your user code After entering your user code you will receive an acoustic message This is as follows Warning An alarm has bee...

Страница 17: ...to listen connection 3 Switch to listen connection and repetition of the alarm message 5 End call to the phone number 9 End all calls 5 If you are able to take action yourself acknowledge the alarm tr...

Страница 18: ...oh three times Alarm Pip pip pip pip pip Reset required 17 User menu The user menu is graphically designed to be used almost intuitively The control buttons are used to navigate around the user menu...

Страница 19: ...he user code omit zones record voice messages read the log activate control functions and test detectors Some functions may have been blocked for the user by the installer The following table lists al...

Страница 20: ...ce Memo menu item By pressing Select you can record a voice message If Select was confirmed using the control button recording begins and the following graphic display is shown Recording can be stoppe...

Страница 21: ...wireless alarm system is activated The next time the alarm system is deactivated these zones are automatically included again and have to be removed again from monitoring manually 18 5 Installing use...

Страница 22: ...mmands Add a remote control to the user Social Care Add a pendant to the user Panic Add a panic transmitter to the user Alternatively you can also use the dual key function of the remote control Exit...

Страница 23: ...changes to the system settings 18 5 1 3 Defining partitions User authorisations are defined in this menu In this way different users can control different partitions The settings also refer to the chi...

Страница 24: ...the code is saved 18 5 1 5 Training and removing chip keys remote controls pendants and panic transmitters Follow the instructions in the display to train the corresponding components to the wireless...

Страница 25: ...to 20 remote control units FU8100 FU5155 5150 can be trained More than one remote control can be assigned to a user Training the wireless cylinder Select Telecommands The system prompts you to train t...

Страница 26: ...h as remote controls and chip keys select the Delete User menu item Select the corresponding user by pressing Delete Confirm your entries by pressing OK The user is then deleted Please note that at le...

Страница 27: ...amper The tamper contact of the housing lid was opened Lid Tamp Restore The tamper alarm of the housing lid was confirmed Telecmd U Low Bat The remote control battery of user must be replaced Pendant...

Страница 28: ...aning PSTN Line Restore Error in analogue telephone line was confirmed PLGON Line Restore Error in ISDN GSM transmission was confirmed Comms Fail Error during transmission to security centre U Remote...

Страница 29: ...deactivates the voice prompt Activity Monitor Activates and deactivates activity monitoring of the social care call B Light Brightness Sets the backlight brightness in 4 steps B Light Always Backligh...

Страница 30: ...eactivate the siren On or Off at the top right of the display indicates whether or not the siren should be heard Loudspeaker Press Play Stop to play the voice messages over the loudspeaker You can lis...

Страница 31: ...all keys on the remote control one after another Pendants Press the button on the pendant The identity of the user assigned to the pendant is displayed PA Detector Press the button on the panic transm...

Страница 32: ...installed Summer Winter Time Selects between automatic and manual change from summer to winter time Message Volume Selects the volume of the voice message Panel Sounder Vol The volume of operating inf...

Страница 33: ...data records can be programmed for activation start and 5 data records can be programmed for deactivation end Monday Tuesday Wednesday Thursday Friday Saturday Sunday Time P1 P2 P3 P4 P1 P2 P3 P4 P1 P...

Страница 34: ...ecting the weekday In the System Config menu select the Auto Set Unset menu item Access the menu and enter your access code Select the weekday in the week planner Monday Tue sday Wednesday Th Time P1...

Страница 35: ...rm with OK Select the Partitions menu item then change the partitions to Y or N Go Back and select the Auto Unset menu item Monday Tuesday Time P1 P2 P3 P4 P1 P2 P 00 00 00 00 01 00 02 00 03 00 S 04 0...

Страница 36: ...ion time Set the hour then press Next to set the minutes and confirm with OK Select the Partitions menu item then change the partitions to Y or N End programming by pressing Done Monday Tuesday Time P...

Страница 37: ...ctivation time 19 59 and Partitions 1 Create data record 3 as detailed in the Auto Set and Auto Unset sections Set Y activation time 20 00 Part Set N and partitions 1 Unset time 07 20 on the following...

Страница 38: ...record Start deactivated End deactivated Monday Tuesday Time P1 P2 P3 P4 P1 P2 P 00 00 00 00 01 00 02 00 03 00 S 04 00 05 00 06 00 07 00 07 20 07 20 08 00 09 00 10 00 11 00 12 00 13 00 14 00 15 00 16...

Страница 39: ...me number can also be changed in the user menu Select the Follow Me menu item Enter the new number on the keypad and save by pressing OK Press Delete to delete a phone number 18 11 Outputs On Off Thi...

Страница 40: ...errors do not immediately trigger an alarm or prevent system activation All errors should be cleared immediately by the user or reported to the installer as they indicate a malfunction Errors and erro...

Страница 41: ...nnection between the mains power line and the PSU clamp Contact your installer WAM__PSU Fail 230 V AC power supply is missing in the accessory module The mains power cable to the 12 V power supply is...

Страница 42: ...on Contact your installer Jamming Jamming of wireless communication for more than 30 seconds inside a minute Intentional or natural disturbance within the wireless band Contact your installer PSTN Lin...

Страница 43: ...eclaration of conformity The declaration of conformity to the applicable guidelines has been made available and signed by Security Center management It is available under www abus sc eu 21 User menu o...

Страница 44: ...44...

Страница 45: ...A1 I Amendments to the operating manual UK Secvest 2WAY FU8006 S W 5 04 22...

Страница 46: ...ftware release for the Secvest 2WAY includes optimised workflows and an extended function range These improvements can be found in the following document 2 Software status 01 08 2009 The information a...

Страница 47: ...ing Secvest Key 2WAY Door Lock 1 Door Lock 2 Door Lock 3 or Door Lock 4 The wireless cylinder functions can be tested here Unlocked is shown on the Secvest 2WAY display when the door is unlocked Locke...

Страница 48: ...et under the following positions are started when the remote control is pressed Installer Menu Partitions Partition 0x Ext Mode Timed Set Final Door Set Instant Set Silent Set The exit delay time is s...

Отзывы: