9
Using the
control button, select the item under
View
to display the error.
The following graphic display is shown:
The wireless alarm system now shows all zones that are open or have an
error. The entry following the zone number directly in front of the zone name is
important here. These entries have the following meanings:
A:
Alarm
T: Tamper
Close the zones until the display shows
0Faults
, or omit the zones and
remove them from surveillance.
8.2. Notes on system activation with compulsory hidden
(omitted) zones
In order to facilitate system operation, it is possible to hide open zones
automatically when the system is activated. It is then possible to leave the
premises for a short time without needing to close all doors and windows.
Omitted zones remain hidden for the entire activation period and do not trigger
any alarms.
IMPORTANT:
Only important entry and exit zones should be automatically omitted (e.g. front
door, cellar door, back door etc).
Automatic omission of zones can be made in two ways:
a) Automatic omission with confirmation
b) Automatic omission without confirmation
Automatic omission with confirmation
System is activated by:
•
Fast
activation
•
Remote
control
•
Arming
station
•
Chip
key
•
Wireless
cylinder
The following display is shown:
An acoustic warning is also issued. This is as follows:
“The alarm system cannot be activated”
When this message is heard, all opened zones with the “FS” (Force Set) zone
attribute can be automatically omitted in the following ways:
•
By pressing the active key on the remote control again
•
By entering your user code and pressing the active key on the remote
control
The alarm system is then activated.
Automatic omission without confirmation
System is activated by:
•
Fast
activation
•
Remote
control
•
Arming
station
•
Wireless
cylinder
All opened zones with the “FS” (Force Set) zone attribute are automatically
omitted and the alarm system is activated.