EN
36
Vario metering valve AXDV-V1-EL:
PIN Function
Description
1
24 V DC
Power supply
2
TX
RS232 serial interface
3
0 V DC
Ground reference potential
4
RX
RS232 serial interface
5
Input
3rd input
6
Input
Analogue input 0-10 V / 0-20mA ²
)
7
Output
Error output
8
nC
Do not connect!
²
)
By default, the analogue input is 0-10 V. Unscrewing
the connection cover reveals a switch on the print. For
0-10 V input, the switch must be set to the left (marking
U). For 4-20mA input, the switch must be set to the right
(marking I).
Connection plan Vario-V1
At least a three-cored, shielded electric wire with the delivered male plug is
connected like shown on the connection plan
The other end of the cable is connected with the power supply as well as the
Control.