| Installation –
Installing the eMH3 Wallbox on the POLEMH6
26
4
Loosen the screw holding the internal electronic
components cover in place using a Torx screwdriver
and put it aside.
y
Keep the screw in a safe place.
5
Insert the power supply cable into the housing
through the large grommet.
y
For wiring up group installations, you must also
insert the data cables into the housing through
the small grommets.
6
Insert the individual conductors of the power sup-
ply cable into the respective terminals of the RCCB
and tighten them using a screwdriver (torque: 2.5
to 3 Nm).
y
End ferrules must be fitted on flexible
conductors.
y
Operate the spring-loaded mechanism of the
PE terminal and attach the protective earth
conductor.
y
Use the connection patterns listed on page 29
to allocate the individual conductors.
1,5 m
NOTE
Detailed information in the installation instructions
The installation instructions for the eMH3 Wallbox contain detailed information on preparing for the electrical
connection.