| Installation –
Installing the eMH1 Wallbox on the POLEMH1
20
3
Remove the upper part of the housing from the
housing base.
4
Connect a supply cable measuring approximately
1.5 metres in length to the internal RCCB or termi-
nal block (basic models) of the eMH1.
y
To establish the connection, the grommet of the
wallbox must be cut and the supply cable insert-
ed into the interior of the housing.
1,5 m
NOTE
Detailed information in the installation instructions
The installation instructions for the eMH1 Wallbox contain detailed information on preparing for the electrical
connection.
5
Remove the right-hand grommet on the front of the
mounting pole, use the cutter to cut an opening for
the supply cable in the membrane of the grommet
and then replace it.
y
If you also want to lay data cables into the
wallbox, cut the left-hand grommet, too.
6
Using the hexagon screwdriver, screw one of the
supplied M6×16 screws into the upper fixing point
of the POLEMH1.
y
The distance between the bottom of the screw
head and the mounting pole must be 4 mm.
4 mm