appendix
23
MODEL VARIANT
EVSE 552
EVSE 562
EVSE 572
Compliance
IEC 61851-1/22
Rated voltage
230/400 V 50 Hz
230 V 50 Hz
Rated current
32 A (MCB required onsite)
Max output
22 kW
7.2 kW
Charging socket
Type 2, lockable
Circuit-protection devices
external RCCB
required onsite
RCCB, Type A, 30
mA and electronic
DC fault current
detector DC-RCM,
I
Δ
n d.c.
≥
6 mA
Energy meter
not included
Control / Customization
internal RS485-interface
Terminal block
up to 6 mm
2
Operating temperature
-30°C to 50°C
Storage temperature
-30°C to 85°C
Relative humidity
5 to 95% (no condensation)
Class of protection
I
Degree of protection
(housing)
IP44
Overvoltage category
III
II
Dimensions
272 x 220 x 106 mm (H x W x D)
Weight per unit
ca. 2.3 kg
WARNING!
Please note that the charging stations of the
eMH1
series are available
in a range of model variants with differing technical data. The information
and technical specifications in this manual refer exclusively to the model
variant mentioned in these instructions and must NOT UNDER ANY CIR-
CUMSTANCES be transferred to other
eMH1
model variants.
Standards & guidelines
Your eMH1-EVSE 5X2 charging station complies with the following standards and
classes of protection:
General standards
STANDARD
DESCRIPTION
2004/108/EC
EMC Guideline
2002/95/EC
RoHS Guideline