reSOlving errOrS
19
PLEASE NOTE:
All EVSE model variants must be protected during operation either
by an integrated or external RCCB.
Depending on the country, for model variants without DC fault current
detection, an external type B RCCB must be set aside in the domestic
power distribution box.
To take suitable measures and restore operation in case of malfunction, you must first
clearly identify the type of error.
The following errors may occur:
TYPE OF ERROR POSSIBLE CAUSE
SUGGESTED SOLUTION
LEDs are not
functioning.
The EVSE 5X2 does not
have a power supply.
The power supply of the EVSE 5X2 is
interrupted within the domestic electri-
cal infrastructure: Check the upstream
circuit breaker in the domestic power
distribution box.
The internal or the external upstream
RCCB of the EVSE 5X2 has been
tripped: Check the status of the RCCB
and, if necessary, switch it back on using
the pivot lever .
The indicator LEDs
of the EVSE 5X2 are
faulty.
Should the indicator LEDs of the EVSE
5X2 be faulty, they must be replaced.
In this case, please contact your local
distributor.
The electric
vehicle is not
recognized.
The charging cable is
not properly plugged
into the vehicle or the
charging station.
Remove the charging connector from
the vehicle and the charging station and
plug it back in: Ensure that the connec-
tors are placed in the vehicle and charg-
ing station sockets correctly.
The vehicle is wrongly
configured.
Check the vehicle settings and, if neces-
sary, reset them (to factory settings).
The indicator
LEDs show
an error se-
quence.
The EVSE 5X2 detects
a malfunction.
All error codes shown by the indicator
LEDs of the EVSE 5X2 relate to vehicle-
based functions (see page 18). The
EVSE 5X2 reinitiates the charging pro-
cess every 30 seconds: Should the error
persist, please contact your service
partner for the vehicle.