![ABL 3W2205 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/abl/3w2205/3w2205_installation-manual_452118028.webp)
appendIx
24
Model Variant
3W2214
3W2217
3W4401
Compliance
IEC 61851-1 / 61439-7
Grid connection
Direct connection to residual current circuit
breaker (RCCB)
PE: Feed-through terminal block, max. 5 x 10
mm²
for two supply cables of
max. 5 x 10 mm² each
Rated voltage
230 / 400 V
Rated current
32 A, 3-phase
2 x 32 A, 3-phase
Rated frequency
50 Hz
Max output
2 x 11 kW or 1 x 22 kW
2 x 22 kW
Charging outlet
Lockable Type 2 charg-
ing socket in acc. with
IEC62196-2, 2 pcs.
Type 2 charging socket
with shutter in acc. with
IEC62196-2; 2 pcs.
Lockable Type 2 charg-
ing socket in acc. with
IEC62196-2, 2 pcs.
Circuit-protection
devices
Type A 30 mA RCCB, and DC-RCM IΔn d.c.
electronic DC fault current detector
≥ 6 mA
Control /
Customization
Internal RS485 and USB interfaces
(no user access)
Operating temperature
-30°C to 50°C
Storage temperature
-30°C to 85°C
Relative humidity
5 to 95% (no condensation)
Class of protection
I
Overvoltage category
III
Degree of pollution
3
Degree of protection
(housing)
IP54
Impact strength
IK08
Dimensions incl
Mounting plate
492 x 400 x 192 mm
(H x W x D)
Dimensions
w/o mounting plate
492 x 400 x 162 mm
(H x W x D)
Mounting plate dimen-
sions
477.9 x 376.4 x 32 mm
(H x W x D)
Maximum elevation
≤ 2,000 m AMSL (above mean sea level)
Weight per unit incl
mounting plate
ca. 5.7 kg
Weight per unit
w/o mounting plate
ca. 4.7 kg