MODEL NUMBER GRID CONNECTION MODEL VARIANT
3W2214
230 / 400 V
50 Hz 32 A
Twin charging station with two integrated charg-
ing sockets according to IEC 62196-2 Type 2
with locking mechanisms for separately avail-
able charging cables (Type 2 to Type 2 or Type
2 to Type 1); integrated, factory deactivated
RFID module for access control; internal Type A
RCCB; internal DC fault current detection; inter-
nal load management for charging outputs of up
to 2 x 11 kW or 1 x 22 kW
3W2217
230 / 400 V
50 Hz 32 A
Twin charging station with two integrated charg-
ing sockets according to IEC 62196-2 Type
2 with shutters and locking mechanisms for
separately available charging cables (Type 2 to
Type 2 or Type 2 to Type 1); integrated, factory
deactivated RFID module for access control;
internal Type A RCCB; internal DC fault current
detection; internal load management for charg-
ing outputs of up to 2 x 11 kW or 1 x 22 kW
3W4401
230 / 400 V
50 Hz 2 x 32 A
Twin charging station with two integrated charg-
ing sockets according to IEC 62196-2 Type 2
with locking mechanisms for separately avail-
able charging cables (Type 2 to Type 2 or Type
2 to Type 1); integrated, factory deactivated
RFID module for access control; internal Type A
RCCB; internal DC fault current detection; charg-
ing output of up to 2 x 22 kW
WARNING!
The information and technical specifications contained in this manual re-
late exclusively to the above-mentioned model variants and must not be
transferred to other wallbox models. Should your wallbox variant not be
described in this manual, please contact ABL technical support. Do not
under any circumstances install the wallbox in this case, as this could
lead to damage to the wallbox, to injury and/or death.
General requirements of the installation site
Your ABL Wallbox is an electrical device and is therefore subject to particular require-
ments for indoor and outdoor installation. In selecting the installation site, you must
consider the following points:
• Consider all local regulations for electrical installations, fire protection and accident
prevention.
• The wallbox must be installed where it is freely accessible to all authorized users.