EN - 13
PSB
5 Putting into operation
5.5 Connecting the plasma cutting torch
1
Handle tube AUT
2
Electrode
3
Plasma nozzle ø1.0; 1.3; 1.5; 1.8; 2.0
4
Spring receiver
5
Electrode wrench
6
General purpose wrench
Fig. 3
AUT PSB 60 and AUT PSB 121
AUT PSB 60
AUT PSB 121
1
2
3
4
5
6
NOTICE
• Make sure that the connections are properly assigned and tightened.
• Since the plasma nozzle cannot be protected against direct contact for
technical reasons, the plasma cutting power source must fulfil the
requirements of EN 60974-7, point 7.4.2.
• The plasma cutting torch in connection with the plasma power source
must conform to EN 60974-10.
• The plasma power source must also conform to EN 60974-1.
• The plasma power source and cutting torch must have the same type of
ignition (contact or HF) and the same output power (rated current and
corresponding duty cycle).
Tab. 3 on page EN-5