iROB
®
501, iROB
®
401, iROB
®
301
6 Putting into operation
EN
-
23
Description for setting 9
Short-circuiting the terminals shifts the previous job no.
The job no. is shifted to the previous no. and this parameter set is read out when the terminals are short-
circuited for 100 ms during shift mode. Since the job no. has reached the lowest value, it will jump to the
highest value.
If a job no. does not contain any welding parameters, it is skipped. The parameters cannot be changed
during welding. To cancel shift mode, the external output terminals must be open. The digital display shows
current and voltage after 1 second.
Description for setting 10
By activating this function, it is possible to detect a fault in the cool air flow rate of the power unit.
Description for setting 11
By activating this function, it is possible to detect a warning in the cool air flow rate of the power unit.
Содержание iROB 501
Страница 81: ...iROB 501 iROB 401 iROB 301 Notizen DE 81 Notizen...
Страница 158: ...EN 78 Notes iROB 501 iROB 401 iROB 301 Notes...
Страница 159: ...iROB 501 iROB 401 iROB 301 Notes EN 79 Notes...