iROB
®
501, iROB
®
401, iROB
®
301
13 IFR-800 fieldbus connection tool
EN
-
65
8
0
Voltage setting for
synergetic mode
1: SYNERGETIC mode
0: individual mode
8
1
Setting for wire
feed speed
1: Setting for wire feed
speed
0: Welding current setting
8
2
Setting for wire
feed speed
1: valid
0: invalid
9–10
–
Welding current
Specifies the welding current.
11–12
–
Wire feed speed
Specifies the wire feed speed.
13–14
–
Welding voltage
Specifies the welding voltage.
15
–
Fine adjustment of
welding voltage for
synergetic mode
Specifies the fine adjustment of welding voltage for
synergetic mode.
16–17
–
Wave frequency
Specifies the wave frequency.
18/21/
24/27
–
Function
(port 1 to 4) no.
Sets the function number.
0–6
Function (port 1 to 4)
display change
Changes the function value display.
19–20/
22–23/
25–26/
28–29
–
Function (port 1 to 4)
setting value
Setting for function values.
Tab. 27
Simplified table for output data
Offset
Bit
Function
Description
Содержание iROB 501
Страница 81: ...iROB 501 iROB 401 iROB 301 Notizen DE 81 Notizen...
Страница 158: ...EN 78 Notes iROB 501 iROB 401 iROB 301 Notes...