iROB
®
501, iROB
®
401, iROB
®
301
5 Transport and installation
EN
-
17
4.5 Connections
5 Transport and installation
The device can be transported with a lifting tool.
► Fix the device to the attachment points.
► Slowly lift the device and make sure that it remains balanced during transport.
► Install the device accordingly and lock the casters (for optional driving carriage).
Fig. 10
Connections on the back
A
Data cable for WLAN module (optional)
B
Fieldbus interface (e.g. Ethernet IP)
C
Power supply for WLAN module (optional)
D
Welding torch intermediate cable assembly connection
E
MPP intermediate cable assembly connection
A
E
B
D
C
WARNING
Risk of injury due to improper transport and installation
In the event of improper transportation and positioning, the device could topple over or fall. This may
result in serious injuries.
► Check and wear your personal protective equipment.
► Ensure that all supply lines and cables do not encroach into the area in which employees are working.
► Place the device on a suitable base (flat, solid, dry) on which it will not topple over.
► Note the weight of the device when lifting it.
► Use an appropriate lifting tool with load handling attachment for transporting and installing
the device.
► Avoid abrupt lifting and setting down.
► Do not lift the device over persons or other devices.
► Use the attachment points provided.
NOTICE
Material damage resulting from improper transportation and positioning
Improper transport or installation can cause the device to tip or fall over. This can result in material
damage and irreparable damage to the device.
► Protect the device against weather conditions, such as rain and direct sunlight.
► Protect the device from welding spatter when welding.
► Protect the device from direct jets of sparks when grinding.
► Ensure that the device does not make contact if you pass over edging.
► Use the device only in dry, clean and well-ventilated rooms.
► Maintain a minimum distance of 30 cm from the wall when installing the device to ensure that it is
sufficiently ventilated.