EN - 10
5 Putting into operation
ABIMIG
®
3
Screw down the nut again, tighten using an ABIMIG
®
wrench and cut off
excess length at the handle threaded part so that it protrudes 2 mm.
4
Screw down rotating or repluggable torch neck again at the handle.
ABIMIG
®
W T
For use of steel wires with divided wire guide.
1
Disconnect the cable assembly
on the machine side and lay it out
straight.
2
Unscrew and remove the torch neck
3
Unscrew the insulating piece
from the torch neck seat using a flat head
screwdriver (width approx. 10 mm).
4
Optionally seal the torch neck with the sealing plug
5
Unscrew the nut
6
from the central connector
until reaching the end
stop of the liner’s nipple in the torch.
7
Screw on the nut
1
Torch neck
2
Insulating piece
3
Torch handle
4
Cable assembly
5
Connection nut
6
Nut
7
Central connector
8
Switch key wrench
9
Liner
10
Sealing plug
Fig. 3
Mounting the liner for ABIMIG
®
W T torches
40
14
40°
1
2
3
4
5
6
8
9
7
40
°
53
10
Содержание ABIMIG A155