EN - 12
5 Putting into operation
ABIMIG
®
XX0/XX5
5.2.2 PA liner
For use with aluminium, copper, nickel and stainless steel wires:
1
Lay out
BIKOX
®
cable assembly straight, screw in contact tip or screw
rotating or repluggable torch neck including neck-liner made of brass onto
it.
2
Slide combi-wire guide containing the brass liner first through the BIKOX
®
cable assembly until a noticeable resistance is felt at the liner nipple of the
torch neck or the contact tip.
3
Slide clamp nipple, O-ring and nut onto PA liner and tighten the nut under
tension.
4
Mark overlength of the PA liner in front of the wire feed rolls and cut it off at
the mark using the
ABICOR BINZEL
cutter.
5.2.3 Neck-liner
For use of steel wires with divided wire guide for changeable torch necks (T,
T8, TM, T8M).
1
Unscrew rotating or repluggable torch neck.
2
Screw contact tip into the tip adaptor.
3
Slide in neck-liner and shorten it at the end free of retaining nipple until it
flexibly protrudes
2 mm
from the retaining nipple.
4
Debur the edge of the neck-liner.
5
Slide neck-liner through the torch neck as far as it will go and screw down
the gas nozzle.
6
Retighten the rotating or repluggable torch neck.
NOTICE
• For PA liners of outer diameter 4.00 mm, the capillary tube in the
intermediate joining section must be replaced with a guide tube.
• For changeable and repluggable torch necks and torch necks that
cannot be changed, combined wire guides with integral brass liner are
used.
• For changeable torch necks, a neck-liner made of brass is used.